Indian Journal of Anaesthesia  
About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions
Home | Login  | Users Online: 527  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size    




 
CLINICAL INVESTIGATION
Year : 2009  |  Volume : 53  |  Issue : 3  |  Page : 312-317 Table of Contents     

Our Preliminary Experience with LMAC-Trach


1 Professor & Head, Dept. of Anesthesiology, Medical college, Baroda, India
2 Assistant Professor, Dept. of Anesthesiology, Medical college, Baroda, India

Date of Web Publication3-Mar-2010

Correspondence Address:
Mamta G Patel
6, Yogeshwar Park, Near Swati soc-1, Near Jalaram temple, Manjalpur, Vadodara-390011
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 20640139

Rights and PermissionsRights and Permissions
 

The LMA CTrach is a variant of the intubating LMA. It provides visualization of larynx during intubation and is a promising addition to airway management cart.
A preliminary study of 20 patients posted for elective surgery requiring GA were enrolled for the study. Their age ranged from 16-60 years, weight ranged from 45 to 65 kg, and they were belonging to ASA PS I& II with normal airways. Conventional general anaesthesia was administered in all the cases. The success rate and attempt of insertion of CTrach and ETT were observed. Viewing of larynx was graded as good, acceptable and poor. Require­ment of manipulations was also noted down. Time for insertion of CTrach and ETT, view of larynx and complete procedure were noted down.
We successfully inserted LMA CTrach at first attempt in all the patients within 36.75 ± 2.12 sec and ventilation was possible in all cases. We were able to view larynx in majority of cases (95%), while in 1 patient (5%), we could not view the larynx even after manipulations, although ET intubation was successful in that case. Time required for viewing of larynx was 240.2 ± 10.5 sec. Manipulation of LMA was required in 40% cases to obtain good view. ET intubation was done at first attempt in all the patients within 60.5 ± 5.15 sec. The time required for complete proce­dure was 347.75 ± 10.55 seconds. None of our patient had any complications and haemodynamic parameters and SpO 2 remained within normal limits throughout the procedure. The post operative period was uneventful. We suc­cessfully ventilated and intubated all the patients using LMA CTrach.

Keywords: Equipment, airway; LMA CTrach and ETT, Anaesthesia:GA


How to cite this article:
Swadia V N, Patel MG. Our Preliminary Experience with LMAC-Trach. Indian J Anaesth 2009;53:312-7

How to cite this URL:
Swadia V N, Patel MG. Our Preliminary Experience with LMAC-Trach. Indian J Anaesth [serial online] 2009 [cited 2019 Dec 15];53:312-7. Available from: http://www.ijaweb.org/text.asp?2009/53/3/312/60295


   Introduction Top


LMA C Trach, a modified version of Intubating LMA (ILMA), allows continuous video-endoscopy of the tracheal intubation procedure through LMA. [1],[2],[3] It is a new system for airway management and endotracheal intubation (ETI). This system comprises of LMA with fibreoptic channels and detachable LCD viewer. So, this system enables simultaneous viewing of larynx and process of ET intubation via LMA.

Since its introduction in April 2005 and modifica­tion in December 2005, this device seems to be a prom­ising addition to airway management cart. This LMA C Trach system also enables higher success rate of venti­lation and intubation in difficult airway situations. [2]

Here, we undertook this preliminary study to evalu­ate success rate of Insertion of LMA C Trach, Viewing of larynx and Endotracheal intubation.


   Methods Top


After obtaining institutional approval and written informed consent, total 20 adult patients posted for elec­tive procedures requiring GA were enrolled for the study. This is our preliminary study, so we have taken only 20 cases.

Their age ranged from 16-60 years, weight ranged from 30-65 kg and they had ASA PS I and II. Patients who were pregnant, morbidly obese, non-fasted, who had gastro-esophageal reflux, delayed gastric empty­ing or severe respiratory disease, were excluded from the study. As this was our preliminary study, we did not include patients with anticipated difficult intubation cases (morbidly obese, patients with abnormal airway anatomy and upper esophageal pathology, Mouth opening less than 2 finger breadth) in this study.

LMA C Trach system

The LMA C Trach system is shown here in [Figure 1]. This system comprises of anatomically curved LMA

with airway tube, LCD viewer, epiglottis elevating bar and endotracheal tube. The LMA C Trach has two in built fibreoptic channels to convey light and image. It has an epiglottic elevating bar and an aperture through which the anatomy, anterior to the bar can be viewed. The CTrach is designed so that mask aperture is lo­cated over glottis enabling view of laryngeal structure. The shape of this device is based on MR imaging of human adult airway. The magnetic latch connector at the top of LMA C Trach connects LCD viewer. The viewer has a high resolution 86 mm LCD color display screen and a thumbwheel for adjusting the focus. It also has a rechargeable battery for up to 30 min of continu­ous use with a charger cradle for recharging the viewer.

Pre insertion preparation

Selection of size of LMA C Trach and ETT was done as per patient's body weight as follows­

Size 3 LMA C Trach& 6.0 mm ETT-used for pts with BW-30-50 kg

Size 4 LMA C Trach& 7.0 mm ETT-used for pts with BW-50-60 kg

Size 5 LMA C Trach& 7.5 mm ETT- used for pts with BW->60 kg

Before insertion of LMA C Trach, the cuff of the LMA was fully deflated with the help of cuff deflator. Only posterior surface of LMA was well lubricated with the jelly to prevent obscuring of the fibreoptic channel port.

The LCD viewer was attached to LMA C Trach and focusing was adjusted by obtaining a sharp image of gauze piece or sheet of text held 1 cm in front of the Fibreoptic channel port. Then viewer was detached from the LMA.

Anaesthesia and airway management:

We enrolled 20 adult patients, 16-60 years of age, ASA PS I& II, Mallampati's classification I& II, who required GA with oral ET intubation for elective surgery.

After confirming NBM status, all the patients were pre medicated with glycopyrrolate 0.01 mg.kg -1 IM 30 min before the induction of anaesthesia. Midazolam 0.03 mg.kg -1 and fentanyl 2mcg.kg -1 IV were given 2 min before induction.

After pre oxygenating the patients for 5 min, we induced general anaesthesia with propofol 2.5 mg.kg -1 IV and inhalation of sevoflurane (2% conc.) till loss of eyelash reflex. After confirming of face mask ventila­tion, vecuronium bromide 0.1 mg.kg -1 IV was given for muscle relaxation. Anaesthesia was maintained with sevoflurane + O 2 +N 2 O during the procedure.

After adequate jaw relaxation, C Trach was in­serted by authors who had more than 5 years of expe­rience of insertion of various type of LMAs, the cuff of LMA was inflated with air to achieve airtight seal (size 3 = 20 ml/ size 4 = 30 ml and size 5 = 40ml) and Bain's circuit was connected and ventilation was confirmed by bilateral equal air entry.

Time and attempt required for insertion of C Trach were noted down. After satisfactory ventilation was achieved, the LCD viewer was connected to the C Trach and the view of the larynx was obtained as shown in [Figure 2]. During this period, ventilation via C Trach was continued.

The viewing of larynx was scored as Grade­1(good view), Grade-2 (acceptable view) and Grade­3(poor view). Ease of obtaining view on first attempt was scored as easy, difficult and impossible. In case of inability to view the larynx, manipulation of C Trach was done to obtain the view.

Success of viewing of larynx after manipulation was scored as

  1. View improved - Grade-1(good), Grade-2 (accept­able) and Grade-3(poor)
  2. No change
  3. Worsen/ Impossible


After obtaining a best possible view (could see the vocal cords and laryngeal inlet in the centre of viewer), well lubricated ET tube was inserted through LMA C Trach. The blue colored epiglottis elevating bar (which elevates epiglottis at the time of tube inser­tion) was seen on the screen as seen in [Figure 3]. We used flexible, cuffed, wire reinforced silicone ET Tubes for all the patients. Correct placement of tube was con­firmed by direct visualization on the LCD screen as in [Figure 4] and by chest auscultation. We then inflated the cuff of ETT and detached the viewer, removed the ETT connector, deflated the CTrach cuff and removed the LMA CTrach over the ETT with the use of a stabilizer rod. The ETT connector was then replaced and con­nected to Bain's circuit for IPPV. Again, ventilation via ETT was confirmed by equal air entry. The [Figure 5] and [Figure 6] show complete process of intubation via LMA­CTrach.

Various observations made in this study were as follows -

Time T1- Time required from picking up of LMA CTrach up to its Insertion and confirmation of place­ment of LMA.

Time T2- Time required from insertion of LMA up to achievement of view of larynx in the LCD Viewer.

Time T3- Time required from achievement of view of larynx up to insertion of ET tube through LMA.

Time T4- Total Time required from insertion of LMA and insertion of ETT through LMA.

We also observed conditions during the procedure like -

  • No. of attempts for C Trach insertion& successful ventilation,
  • Ease and quality of obtaining view of larynx,
  • No. of attempts for intubation and
  • No. of intubation without proper view through C Trach and


Intra operative monitoring was done for pulse rate, blood pressure, SpO 2 .Changes in vital parameters and SpO 2 , any complication occurred, were also noted. At the end of surgery, reversal was given using neostig­mine 0.5mg.kg -1 and glycopyrrolate10 mcg.kg -1 IV and extubation was done when the criteria was fulfilled.

Statistical analysis was done using Mean and SD to describe parametric data and Rate and Percentages for success rate.


   Results Top


[Table 1] shows various demographic data and [Table 2] shows types of surgery in study. The time re­quired for insertion of LMA CTrach system is shown in [Table 3].

We successfully inserted CTrach LMA at first at­tempt in all the patients in 36.75 ± 2.12 sec. We were able to view larynx in majority of cases (19 patients), while in 1 patient, we could not view the larynx, al­though ET intubation was successful in that case. Thus, insertion of ETT was at first attempt in all the patients in our study. The conditions observed during the proce­dure are as shown in [Table 4]. Vital parameters and oxygen saturation in our study are as shown in the [Table­ 5]. Fall in systolic BP was observed after 10 min in 30% cases which was easily managed with O 2 , IV fluids and by decreasing concentration of sevoflurane. None of our patients developed cyanosis, laryngospasm or lo­cal injury related to procedure. Only in one patient, coughing was observed during intubation. None of our patients developed sore throat or other complication in the postoperative period.

The anaesthesia was uneventful in all the patients.


   Discussion Top


The intubating LMA (ILMA) was invented and bioengineered by Dr. Archie Brain in 1997 using MR scans of the adult airway. [4] This device required at least three hands to intubate trachea and thus became cumbersome procedure. Then, the LMA CTrach was developed to minimize the technical effort required by the user and fiberoptic components are integrated into the ILMA for direct view of the larynx. Thus, LMA CTrach is a new system for airway management and ET intubation.

The LMA CTrach is indicated as an alternative for achieving and maintaining an airway. It seems to be a promising addition to airway management cart and can be used in both anticipated and unexpected diffi­cult airway situations. The use of this system is not suit­able in case of esophageal or pharyngeal pathology and prone position.

In our study, we successfully inserted CTrach in all the patients at first attempt in 36.75 ± 2.12 sec. In our study, the trained anaesthesiologist experienced in insertion of CLMA& PLMA only introduced C Trach LMA. Our results are in consonance with that of Liu EHC et al [1] and that of Timmermann et al [2] .

Considering Viewing of larynx, we obtained good view (grade-1) in 60% cases and acceptable view in 35% patients (grade-2). However, manipulation of CTrach LMA was required in 8 (40%) patients to ob­tain good view in our study and View was improved after manipulation. Only in one patient (5%), view was poor (grade-3). Neither manipulation nor focusing could improve the view and we decided to intubate without vision and were successful in doing so at first attempt via CTrach without proper view.

Liu et al [6] had observed that, out of 100 patients, in 84% patients good view was achieved and 16% cases required manipulations of LMA. Timmermann[2] et al observed that, manipulations required in 63.3% cases. According to them the most frequent causes of poor image quality in 28.3% cases were secretions in front of the lens and an inadequate light intensity. Dhonneur et al [7] had observed that, 49% of patients required manipulation of CTrach resulting in increased duration of tracheal intubation by 57 seconds as com­pared to direct laryngoscopy (DL) in their study. But oxygenation was of better quality in patients managed with CTrach than DL. They observed that, LMA CTrach is only airway that allows ventilation during in­tubation attempts and allows for less stressful situations. In our study, time to achieve view of larynx was more (240.2 ± 10.5 sec) in comparison to Liu [6] et al. We attribute this to our learning phase. In our study, we intubated all the patients successfully at first attempt. Even in case of poor view, we intubated the patient without vision at first attempt. We did not observe any failed intubation.

Liu et [1] al had observed that, out of 100 patients, in 14 patients intubation was done without proper view at first attempt and in 2 patients after three attempts. They were unable to centralize the view of larynx and to align the CTrach with the larynx despite several ma­nipulations. In their study, conventional intubation with Macintosh laryngoscope was carried out in 2 patients (unable to direct ETT into the trachea after three at­tempts). Timmermann et al [2] also observed that tracheal intubation (TI) was successful at first attempt in 71.7% cases. TI without proper view was done in 26.6% cases. In one patient, they failed for intubation and had to use conventional laryngoscopy.

In our study, intubation was carried out within 60.5 ± 5.15 sec and the time is comparable with other stud­ies. Total time required for complete procedure is more in our study (347.75 ± 10.55 sec) as compared to Liu et al as per [Table 3]. This might be because of more time was taken in viewing of larynx.

Hemodynamic parameters and SpO 2 were re­mained within normal limits in our study. None of our patients had any complication related to procedure. Only in one patient, coughing was observed at the time of intubation, which might be because of inadequate effect of muscle relaxant.

Thus, we successfully ventilated and intubated all the patients using LMA CTrach. The CTrach enables nearly continuous ventilation and oxygenation of the patient during the intubation process.

In this preliminary study, we could successfully use the CTrach system for intubation and now we can proceed to use this system for cases with difficult air­way.



 
   References Top

1.Liu EHC, Goy RWL, Chen FG. The LMA CTrach, a new laryngeal mask airway for Endotracheal intubation un­der vision: evaluation in 100 patients.Br J Anaesth 2006; 96:396-400.  Back to cited text no. 1      
2.Timmermann A, Russo S and Graf BM. Evaluation of the CTrach-an intubating LMA with integrated fibreoptic system. Br J Anaesth 2006; 96:516-521.  Back to cited text no. 2      
3.Brimacombe J. Intubating LMA for airway intubation. In Brimacombe J (Ed). Laryngeal mask Anesthesia 2005; Philadelphia Saunders pp. 469-504.  Back to cited text no. 3      
4.Brain AIJ, Verghese C, Addy EV and Kapila A. The intubat­ing laryngeal mask. I : Development of a new device for intubation of the trachea. Br J Anaesth 1997; 79:699-703.  Back to cited text no. 4      
5.Cattano D, Pesetti B, Di salvo C, Giunta F, Liu EHC, Goy RWL and Chen FG. Evaluation of the LMA CTrach. Br J Anaesth 2007; 98:409-409.  Back to cited text no. 5      
6.Liu EHC, Goy RWL, Chen FG. An evaluation of poor CTrach views with a fibreoptic laryngoscope and the effectiveness of corrective measures. Br J Anaesth 2006; 97:878-882.  Back to cited text no. 6      
7.Dhonneur G, Ndoko SK, Yavchitz A, Foucrier A, Fessenmeyer C, Pollian C, Combes X and Tual L. Tra­cheal intubation of morbidly obese patients. LMA CTrach vs. direct laryngoscopy.Br J Anaesth 2006; 97:742-745.  Back to cited text no. 7      


    Figures

  [Figure 1], [Figure 2], [Figure 3], [Figure 4], [Figure 5], [Figure 6]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table­ 5]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
    Introduction
    Methods
    Results
    Discussion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed1247    
    Printed73    
    Emailed0    
    PDF Downloaded259    
    Comments [Add]    

Recommend this journal