Cauda equina syndrome following an uneventful spinal anaesthesia


Department of Anesthesiology and Critical Care, S. N. Medical College, Agra, India

Date of Web Publication9-Mar-2010

Correspondence Address:
Uma Srivastava
Department of Anesthesia and Critical Care, S. N. Medical College, Agra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.60505

Rights and Permissions

How to cite this article:
Jain M, Srivastava U, Saxena S, Singh AK, Kumar A. Cauda equina syndrome following an uneventful spinal anaesthesia. Indian J Anaesth 2010;54:68-9

How to cite this URL:
Jain M, Srivastava U, Saxena S, Singh AK, Kumar A. Cauda equina syndrome following an uneventful spinal anaesthesia. Indian J Anaesth [serial online] 2010 [cited 2020 Mar 31];54:68-9. Available from: http://www.ijaweb.org/text.asp?2010/54/1/68/60505

Sir,

Serious neurological complications after spinal anaesthesia are rare but extremely distressing. We report a case of cauda equina syndrome following spinal anaesthesia in a patient who had no identifiable risk factor.

A young female patient was referred to our hospital with persistent weakness of lower limbs along with bladder and bowel incontinence following caesarean section done 16 days back under spinal anaesthesia. The records revealed that spinal anaesthesia was given in L2-3 interspace with 23 G single use Quincke needle in lateral position with 2.4 ml of 0.5% hyperbaric bupivacaine. Three attempts were made before successful spinal puncture. There was no paraesthesia or back pain during needle placement or drug injection, but blood stained CSF was aspirated at the first attempt. There was adequate surgical anaesthesia after 12 minutes and the 45 minutes of surgical duration was uneventful. In the postoperative period, the anaesthetic effect showed no improvement after 12 hours. She developed faecal and urinary incontinence the next day. A neuro-physician managed conservatively. Seeing no improvement even after 15 days, the relatives brought her to our hospital.

Examination by the neurosurgeon showed bilateral sensory motor deficit of both the limbs with impaired sensation to pinprick in the perineal region. A clinical diagnosis of cauda equina syndrome was made. Lumbosacral MRI showed thickening and clumping of cauda equina nerve roots at L2-3 level [Figure 1] along with post contrast (gadolinium) dural enhancement consistent with the diagnosis of arachnoiditis. There was no epidural abscess, haematoma or spinal canal stenosis. The patient was managed conservatively on heavy doses of steroids. Lower limb weakness gradually improved over three months (Grade 2 motor power).

Cauda equina syndrome is characterized by varying degree of saddle anaesthesia, sphincter dysfunction resulting in faecal incontinence, urinary retention and paraplegia. Although rare, case reports have shown an association with spinal anaesthesia. [1],[2],[3] Damage to nerve roots of cauda equina following spinal anaesthesia may occur due to compression, inflammation, stretching due to abnormal position, direct trauma, and spinal ischaemia or as a result of neurotoxicity of local anaesthetics. [2],[3],[4]

The most likely causes in our case could be neurotoxicity, haematoma or trauma to nerves or spinal cord. We presume that bleeding due to trauma could have resulted in haematoma formation and compression of nerve roots (this was not seen on MRI as it was done after about 18 days of spinal anaesthesia). The blood later would have been absorbed causing clumping of nerve roots and arachnoiditis. [4] Direct trauma to spinal cord or intraneural injection though can produce bilateral limb deficit were unlikely causes as the patient did not have any paraesthesia at the time of spinal anaesthesia. [5] Neurotoxicity of local anaesthetic is usually due to maldistribution [3] In the described patient, the thoracic sensory level block was bilateral and reached T8 level within 12 minutes, thus chances of neurotoxicity are minimal. Other possible causes of cauda equina syndrome after spinal anaesthesia were not identified in our patient.

 
   References Top

1.Ozgen S, Baykan N, Dogan IV, Konya D, Pamir MN. Cauda equina syndrome after induction of spinal anaesthesia. Neurosurg Focus 2004;16:e5.  Back to cited text no. 1      
2.Chabbouh T, Lentschener C, Zuber M, Jude N, Delaitre B, Ozier Y. Persistent cauda equina syndrome with no identifiable facilitating condition after an uneventful single spinal administration of 0.5% hyperbaric bupivacaine. Anesth Analg 2005;101:1847-8.  Back to cited text no. 2      
3.Traore M, Diallo A, Coulibaly Y, Guinto CO, Timbo SK, Thomas JT. Cauda equina syndrome and profound hearing loss after spinal anesthesia with isobaric bupivacaine. Anesth Analg 2006;102:1863-4.  Back to cited text no. 3      
4.Aldrete JA. Neurological deficits and arachnoiditis following neuraxial anesthesia. Acta Anaesthesiol Scand 2003;47:3-12.  Back to cited text no. 4      
5.Yorozu T, Matsumoto M, Hayashi S, Yamada T, Nakaohji T, Nakatsuka I. Dibucaine for spinal anaesthesia is a probable risk for cauda equina syndrome. Masui 2002;51:1151-4.  Back to cited text no. 5      


    Figures

  [Figure 1]


This article has been cited by
1 Persistent cauda equina syndrome after cesarean section under combined spinal-epidural anesthesia: a case report
Xiubin Chen,Zhendong Xu,Rong Lin,Zhiqiang Liu
Journal of Clinical Anesthesia. 2015; 27(6): 520
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed4046    
    Printed93    
    Emailed4    
    PDF Downloaded480    
    Comments [Add]    
    Cited by others 1    

Recommend this journal