Indigenous neonatal facemask


Department of Anaesthesiology, RNT Medical College, Udaipur, Rajasthan, India

Date of Web Publication10-Jul-2010

Correspondence Address:
Lalit Kumar Raiger
Dilshad Bhawan 69, Chetak Circle, Udaipur, Rajasthan - 313 001
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.65356

Rights and Permissions

How to cite this article:
Raiger LK. Indigenous neonatal facemask. Indian J Anaesth 2010;54:266-7

How to cite this URL:
Raiger LK. Indigenous neonatal facemask. Indian J Anaesth [serial online] 2010 [cited 2020 Jul 9];54:266-7. Available from: http://www.ijaweb.org/text.asp?2010/54/3/266/65356

Sir,

This report is to highlight how an emergency situation let to the creation of an indigenous mask to overcome an emergency situation. Routinely, the Jackson-Rees modification of Ayre's T-piece breathing circuit with a Rendell Baker Soucek mask [1],[2] is preferred for ventilation in neonatal anaesthesia, as this mask has a malleable edge to fit on the face with low dead space. [2]th

Following an unfortunate electric short-circuit in one of the paediatric emergency OT, we had to shift the paediatric surgical emergencies to another OT. At midnight, a 3-day-old neonate requiring emergency laparotomy was posted for surgery and as the preparation for anaesthetic induction took place, the neonatal face mask was found missing.

This piece of equipment seems to have been left inadvertently in the disabled OT. Since there was no replacement at that time of the night we created our own indigenous neonatal face mask from empty disposable PVC-made fluid bottle.

The upper part of the bottle (tapering part) was cut transversely [Figure 1]a, keeping the diameter of the bottle such that it comfortably covered the nose and mouth of the baby. Now the cap of the bottle, through which the intravenous drip-set spike is inserted, was cut to fit the patient end of Jackson-Ree's circuit with an angle piece (15 mm) [Figure 1]b.

Cotton and an adhesive tape were fixed to the circumference of the 'face mask' to prevent injury to the face. We were thus able to ventilate the neonate and proceed with anaesthesia uneventfully.

 
   References Top

1.Davies NJ, Cashman JN. Lee's Synopsis of Anaesthesia. 13 th ed. Butterworth-Heinemann: Elsevier; 2006. p. 620.  Back to cited text no. 1      
2.Dorsch JA, Dorsch SE. Understanding anaesthesia equipment. 5 th ed. Batlimore, USA: Williams and Wilkins; 2008. p. 445.  Back to cited text no. 2      


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed1264    
    Printed95    
    Emailed0    
    PDF Downloaded269    
    Comments [Add]    

Recommend this journal