Year : 2011  |  Volume : 55  |  Issue : 3  |  Page : 317-318  

Red plug: An alternative to the blocked ProSeal TM laryngeal mask airway inflation valve


Department of Anaesthesiology, Pain & Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India

Date of Web Publication7-Jul-2011

Correspondence Address:
Bimla Sharma
Sir Ganga Ram Hospital, Old Rajinder Nagar, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.82665

Rights and Permissions

How to cite this article:
Sharma B, Sahai C, Sood J. Red plug: An alternative to the blocked ProSeal TM laryngeal mask airway inflation valve. Indian J Anaesth 2011;55:317-8

How to cite this URL:
Sharma B, Sahai C, Sood J. Red plug: An alternative to the blocked ProSeal TM laryngeal mask airway inflation valve. Indian J Anaesth [serial online] 2011 [cited 2019 Oct 18];55:317-8. Available from: http://www.ijaweb.org/text.asp?2011/55/3/317/82665

Sir,

The ProSeal TM LMA (ProSeal TM laryngeal mask airway - PLMA) is expensive and has a shorter life span than the classic LMA (cLMA). [1] The inflation valve of the PLMA is similar to that of the cLMA, and intubating LMA. It has a white polypropylene core and a stainless steel spring. [2]

We report the successful exchange of seven blocked non-functioning inflation valves with the functioning valves of discarded cLMA/PLMA. The repaired PLMAs were subjected to the tests recommended by the manufacturer before autoclaving and subsequently before use. [2],[3]

Successful replacement of damaged cLMA inflation valves and repair of PLMA inflation line using functioning valves or PVC inflation lines taken from various sources have been reported. [4],[5]

On three occasions, when we failed to get a replacement, we bypassed the non-functioning inflation valve of the PLMA, by using the red plug [Figure 1] to inflate the cuff of the PLMA without any problem. The red plug is a vent device integrated into the inflation valve-pilot balloon assembly of the PLMA. [2],[6] Till date, we have conducted 20 laparoscopic procedures using the red plug to inflate the PLMA cuff without compromising the safety of the patients.
Figure 1: ProSealTM LMA with red plug (a) PLMA with red plug and inflation valve. (b) Damaged inflation valve unit. (c) Red plug in use (directly connected to cuff pressure monitor). (d) Red plug connected to CPM (cuff pressure monitor) with an extension line

Click here to view


Failure to inflate the cuff, secondary to obstruction of the pilot balloon may be due to mechanical blockage (chemical residue, damage to valve by chemical agents used during cleaning or sterilisation, moisture or aging of the valve).[7],[2] The manufacturer recommends discarding reusable LMAs after a maximum of 40 uses or when these devices fail the pre-use check tests. In many institutions, their use may extend beyond the recommended 40 uses or they may be used when the damaged part has been repaired and the LMA has fulfilled the pre-use check tests. [8],[5]

Encouraged by our experience, previous reports, [4],[5] failure of the manufacturer to replace damaged inflation valves and the high cost of the reusable LMAs, we now retain functioning inflation valves of LMAs slated for condemnation.

 
   References Top

1.Doneley S, Brimacombe J, Keller C, von Goedecke A. The ProSeal TM has a shorter life span than the classic TM laryngeal mask airway. Anesth Analg 2005;100:590-3.   Back to cited text no. 1
    
2.Brimacombe J. Laryngeal Mask Anesthesia. Principle and Practice. 2 nd ed. London: WB Saunders; 2005.   Back to cited text no. 2
    
3.LMA-ProSeal TM Instruction Manual. Northfield House, Nothfield End, Henley on Thames, Oxon, UK, The Laryngeal Mask Company Limited, 2002. Available from: http://www.LMACO.com [Last accessed on 2011 Feb 03].  Back to cited text no. 3
    
4.David PM, Andreas WL, Alex TM, Craig MS. Exchanging malfunctioning inflation valves in laryngeal mask airways. Anesthesiology 2001;95:A505.  Back to cited text no. 4
    
5.Kundra P, Nisha B. Damaged ProSeal LMA inflation line can be repaired. Indian J Anaesth 2010;54:481.  Back to cited text no. 5
[PUBMED]  Medknow Journal  
6.LMA- ProSeal TM Supplementary Instructions for Use. The Laryngeal Mask Company Limited, Northfield House, Northfield End, Henley on Thames, Oxon, UK. 2002. Available form:http://www.LMACO.com [Last accessed on 2011 Feb 03].  Back to cited text no. 6
    
7.Wat LI, Brimacombe JR, Gee S. Laryngeal mask airway longevity and pilot-balloon failure. J Clin Anesth 1997;9:432.  Back to cited text no. 7
    
8.Wong DT, McGuire GP. Fractured laryngeal mask airway (LMA). Can J Anesth 2000;47:716.  Back to cited text no. 8
    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed1692    
    Printed89    
    Emailed0    
    PDF Downloaded258    
    Comments [Add]    

Recommend this journal