Central venous catheter rotation malposition: An unusual presentation


1 Department of Anaesthesia and Intensive Care, St. Stephen's Hospital, Tis Hazari, Delhi, India
2 Department of Anaesthesiology & Critical Care, S.G.P.G.I., Lucknow, Uttar Pradesh, India
3 Department of Radiodiagnosis, St. Stephen's Hospital, Tis Hazari, Delhi, India
4 Department of Neurosurgery, St. Stephen's Hospital, Tis Hazari, Delhi, India

Date of Web Publication8-Sep-2012

Correspondence Address:
Gaurav S Tomar
Department of Anesthesia and Intensive Care, St. Stephen's Hospital, Tis Hazari, Delhi - 110 054
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.100856

Rights and Permissions

How to cite this article:
Tomar GS, Tiwari AK, Jain DG, Chawla S, Sinha R. Central venous catheter rotation malposition: An unusual presentation. Indian J Anaesth 2012;56:415-7

How to cite this URL:
Tomar GS, Tiwari AK, Jain DG, Chawla S, Sinha R. Central venous catheter rotation malposition: An unusual presentation. Indian J Anaesth [serial online] 2012 [cited 2020 May 31];56:415-7. Available from: http://www.ijaweb.org/text.asp?2012/56/4/415/100856


   Introduction Top


Central venous catheterization (CVC) via infraclavicular subclavian approach in neurosurgical patients is very common practice in view of prolonged surgery and related blood loss that may occur during surgery. The most common malposition related to subclavian vein catheterization is entrance into the internal jugular vein (IJV). [1] Cannulation by the right subclavian vein is associated with the highest risk of malposition of approximately 9.1%. [2] We report a case of malposition of central venous catheter which was internally rotated inside the vessel. We discuss the possibility of its occurrence at the time of cannulation and potential consequence of such an incident.


   Case Report Top


A 60-year-old, 70 kg male patient presented in emergency department with complaints of acute onset vertigo, headache and ataxia and was diagnosed to have a posterior fossa tumour on contrast enhanced computed tomography scan (head). He was subsequently worked up for elective craniotomy and excision of tumour the next morning. His routine investigations and vital parameters were found to be within normal limits. As part of pre-operative monitoring, a subclavian vein central venous cannulation by infraclavicular route was planned. A central venous catheter (16-18-18Ga, 7 Fr, 20 cm, triple lumen; certofix, B Braun) was inserted via right subclavian vein by Seldinger technique under aseptic precautions by the anaesthesia registrar in the operating theatre with HR, NIBP, SPO 2 and ECG monitoring. Passage of the catheter was smooth and unimpeded. There was a good central venous pressure (CVP) waveform and good back flow of blood on aspiration from all the three lumens. The rest of the general anaesthesia and surgery were uneventful. CVP readings were taken 30 min apart and each time a good waveform was noted. As part of routine protocol, a portable chest X-ray was performed before shifting the patient to the neuro-intensive care unit for further monitoring and observation. On reviewing the chest X-ray by the anaesthesiologist, the CVP catheter was found to be internally rotated inside the right proximal internal jugular vein. However, it followed the normal path of right brachiocephalic vein to superior vena cava.

Since blood could be aspirated from all the three lumen ports, central venous pressure was measured with a normal CVP waveform and IV fluids/drugs could be infused via the same catheter, we intended to continue with the same central line for the further management of patient. Further course of the patient in the hospital was uneventful. CVC was removed from its site in the neurosurgery-ward when the patient was planned to be discharged after two weeks of surgery.


   Discussion Top


One of the commonest indications of central venous catheterization is to measure CVP for the purpose of adequate fluid replacement in place of blood and fluid loss in perioperative period. [3] In neurosurgical patients preferred route of central line cannulation is via right subclavian vein because of ease of insertion, low complication rate and erroneous increased CVP related to the IJV route cannulation. A fairly common complication is malposition of the catheter. [4] The most common site of malposition is at the entrance into the internal jugular vein. [1] Lumley and Russell reported that neck compression is a useful test for diagnosing this complication because neck compression on the side of malposition will impede the flow in the vein. This will result in a rise of 10 cm H 2 O or more in CVP reading. [5]

In neurosurgical patients, perioperative monitoring of CVP is deemed necessary in view of anticipated prolonged surgery because of neglected third space fluid and blood losses consequently leading to sudden unanticipated hemodynamic instability (hypotension, tachycardia) that compromises cerebral perfusion pressure. In addition to this, CVC have also been used to aspirate air in case of venous air embolism during neurosurgical procedures in the sitting position particularly involving the posterior fossa and cranio-cervical region.

On the basis of a good CVP waveform and good blood back flow, the anaesthesiologist assumed that the catheter was in correct position. It has been suggested that clinical criteria may not be reliable enough for ascertaining satisfactory catheter tip position. [1],[6] Also, there was no radiological verification of correct placement in this patient until the postoperative period.

In our patient, central line was not exactly malpositioned into the internal jugular vein, but it was initially inserted in IJV proximally later eventually internally rotated to follow its normal course via right brachiocephalic vein into the superior vena cava [Figure 1]. The most probable explanation of its unusual course could be either that the J-tip of Seldinger wire might have been positioned cephalad and thus the catheter 'went up a little bit' into IJV before moving down the superior vena cava as originally intended. The second possible explanation could have been that the catheter followed the path of the already internally rotated guide wire in situ. Since in our case the whole perioperative period was uneventful with regular normal CVP monitoring and IV fluids/drugs access, we continued with our CVC and that there can be a possibility of such internal rotation of central venous catheter inside the vessel. We recommend directing the J-tip of Seldinger wire caudad might minimize or avoid this unusual presentation.
Figure 1: Thick downward arrow: Central venous catheter directed into right internal jugular vein; Thin side arrow: Directed into right brachiocephalic vein and superior vena cava

Click here to view


Ultrasonography reliably detects the guide wire during CVC placement and visualization of the wire before dilation and catheter insertion with almost 100% sensitivity and specificity, may provide an additional measure of safety during central venous catheterization. [7] Its now has been a standard practice in intensive care units and operation theatres.


   Conclusion Top


To conclude, this case report aims to bring to attention the possibility of malposition and internal rotation of CVP catheter inside vessels at the time of insertion of central venous catheter. Although the continuous or frequent (every 10-15 minutes) intraoperative CVP waveform monitoring is important in detecting catheter migration or malposition, (unfortunately not so frequent in our case) we reiterate the importance of radiological verification of CVP catheter position just after or at the time of cannulation of central line.

 
   References Top

1.Langston CS. The aberrant central venous catheter and its complications. Radiology 1971; 100:55.  Back to cited text no. 1
[PUBMED]    
2.Pikwer A, Bååth L, Davidson B, Perstoft I, Akeson J. The incidence and risk of central venous catheter malpositioning: A prospective cohort study in 1619 patients. Anaesth Intensive Care 2008;36:30-7.  Back to cited text no. 2
    
3.Sykes MK. Venous pressure as a clinical indication of adequacy of transfusion. Ann R Coll Surg Engl 1963;33:185-97.  Back to cited text no. 3
[PUBMED]    
4.Lee TL. Malposition of central venous catheter. J Anesth 1988;2:101-9.  Back to cited text no. 4
[PUBMED]    
5.Lumley J, Russell WJ. Insertion of central venous catheters through arm veins. Anaesth Intens Care 1975;3:101-4.  Back to cited text no. 5
[PUBMED]    
6.Johnston AO, Clark RG. Malpositioning of central venous catheter. Lancet 1972;2:1395-7.  Back to cited text no. 6
[PUBMED]    
7.Stone MB, Nagdev A, Murphy MC, Sisson CA. Ultrasound detection of guidewire position during central venous catheterization. Am J Emerg Med 2010;28:82-4.  Back to cited text no. 7
[PUBMED]    


    Figures

  [Figure 1]


This article has been cited by
1 A Rare Central Venous Catheter Malposition: A Case Report
Ali Asghar Moeinipour,Ahmad Amouzeshi,Marjan Joudi,Mehdi Fathi,Saeed Jahanbakhsh,Saeed Hafez,Azra Izanloo,Mahmood Khorsand
Anesthesiology and Pain Medicine. 2014; 3(3)
[Pubmed] | [DOI]
2 Letter to Editor on A Rare Central Venous Catheter Malposition
Jason Lie,Manjula Yadagiri,Catherine Aspinall
Anesthesiology and Pain Medicine. 2014; 4(4)
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
   Introduction
   Case Report
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed2929    
    Printed55    
    Emailed0    
    PDF Downloaded486    
    Comments [Add]    
    Cited by others 2    

Recommend this journal