Successful management of difficult airway in children with the use of adult fibreoptic bronchoscope


1 Department of Anaesthesiology and Critical Care, Apollo Hospitals, Bengaluru, Karnataka, India
2 Department of Plastic and Cosmetic Surgery, BGS Global Hospitals, Bengaluru, Karnataka, India
3 Division of Neuroanaesthesiology and Critical Care, Apollo Hospitals, Bengaluru, Karnataka, India

Date of Web Publication16-Jan-2015

Correspondence Address:
Dr. Keshavan H Venkatesh
Senior consultant, Division of Neuroanaesthesiology and Critical Care Apollo Hospitals, 154/11, Opposite IIMB, Bannerghatta Road, Bengaluru - 560 076, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.149453

Rights and Permissions

How to cite this article:
Rao L, Jumana H, Gururajrao M, Venkatesh KH. Successful management of difficult airway in children with the use of adult fibreoptic bronchoscope. Indian J Anaesth 2015;59:50-1

How to cite this URL:
Rao L, Jumana H, Gururajrao M, Venkatesh KH. Successful management of difficult airway in children with the use of adult fibreoptic bronchoscope. Indian J Anaesth [serial online] 2015 [cited 2020 Feb 18];59:50-1. Available from: http://www.ijaweb.org/text.asp?2015/59/1/50/149453


   Introduction Top


Airway management in children has always been challenging. Various airway devices are used for successful airway management. Fibre optic bronchoscopy is considered as a standard technique in an anticipated difficult airway. Intubating laryngeal mask airway (ILMA), bullard laryngoscope, lighted stylet, glidescope and video laryngoscope are all used to aid intubation. Adult fibreoptic bronchoscope as an aid to intubation in children has been used. We describe successful management of difficult airway in children, using adult fibreoptic bronchoscope as an aid to tracheal intubation.


   Case Reports Top


Case 1

This was a case of a 10-year-old female child, a known case of Treacher-Collin's syndrome (TCS), scheduled for pinna reconstruction. Her airway examination revealed retrognathia, reduced thyromental distance, adequate mouth opening, crowded and protruding upper incisors suggestive of difficult airway. Plan of anaesthesia was inhalational induction with sevoflurane and intubation under deep plane of anaesthesia with a modified technique using adult fibreoptic bronchoscope. All the essential equipment needed for difficult airway management including emergency tracheostomy was kept ready. The child was induced with sevoflurane in oxygen. She was premedicated with injection glycopyrrolate 0.2 mg intravenously. Adequate ventilation with bag and the mask was confirmed. A check laryngoscopy revealed a Cormack Lehane grade 4. Initial attempt to visualise the cords through a fibreoptic bronchoscope failed. A size 2.5 laryngeal mask airway (LMA) was placed and the patient was ventilated successfully. Continuing with the LMA was not considered as the duration of surgery was long and wanted to have a secure airway. An attempt to pass a bougie through the LMA failed. Attempt to intubate the trachea with cuffed 5.0 mm portex endotracheal tube (ETT) through the LMA also failed. As paediatric fibreoptic bronchoscope was not available, the adult fibre optic bronchoscope (FOB) was passed through the LMA and the glottic opening was visualised. An angiographic catheter was passed through the side port of the bronchoscope [Figure 1]a and advanced beyond the vocal cords under vision. The FOB was withdrawn while stabilising the catheter. The ETT 5.0 mm was railroaded over the catheter and passed through the LMA into the trachea [Figure 1]b. The ETT was pushed as far as possible and LMA was withdrawn slowly. Once the ETT came in to view, it was stabilised to prevent extubation during removal of LMA [Figure 1]c. The tube placement was confirmed by capnography. The surgery lasted for 6 h. The trachea was extubated once child was fully awake. Child presented 2 months later for reconstruction of the other ear and airway was managed in the similar way successfully.
Figure 1: (a) Angiographic catheter passed through the side port of the fibreoptic scope, (b) endotracheal tube passed through the laryngeal mask airway (LMA), (c) LMA withdrawn and endotracheal tube stabilized, (d) guide-wire of sufficient length

Click here to view


Case 2

An 8-year-old boy with unstable C2-C3 subluxation was scheduled for C2-C3 posterior fusion. As restriction of the cervical spine movement was desirable, fibreoptic aided intubation was planned. We employed the same technique described above. In this patient fibreoptic scope was passed through the vocal cords and a stiff guide-wire was passed through the side port of the scope and the FOB was withdrawn stabilising the guide-wire. A 5.5 mm cuffed flexometallic reinforced tube was railroaded over the guide-wire and trachea intubated. The tube placement was confirmed by capnography. Surgery was uneventful and child extubated following the procedure.


   Discussion Top


The greatest challenge faced by the anaesthesiologist in patient with TCS is the airway management. There are several reports that the airway becomes progressively more difficult as the age of the patient advances. [1] Goel, et al., [2] have used conventional laryngoscopy with backwards upwards rightwards pressure manoeuvre to intubate. Intubating aides such as lightwand, glidescope, intubating LMA have been used. [1],[3] Kovac [4] has demonstrated the use of Augustine stylet in a patient with TCS. Gharbaghian, [5] reported the use of ILMA for intubation. However, ILMA is not available in a smaller size. Muraika, et al., [6] have performed successful fibreoptic intubation through LMA in paediatric patient. We restrained from using LMA in the second case as there are reports of movement at C2-C3 spine during LMA insertion and placement. [7]

Both our patients were cases of anticipated difficult airway. In the first case we passed the FOB through the LMA and then the angiographic catheter through the side port of the scope and in the second case fibreoptic scope was directly inserted and a stiff long guide-wire was inserted through the side port. Heard, et al., [8] had described similar technique of intubation using LMA as a conduit for fibreoptic scope. We used a stiff and 130 cm long guide-wire to ensure that FOB could be withdrawn without losing the guide within the scope [Figure 1]d. This technique can be safely employed in the management of difficult airway in children.


   Conclusion Top


Use of adult fibreoptic bronchoscope in paediatric airway management has been described. This can be adopted safely as an alternative in paediatric patients to access airway in constraint situations.

 
   References Top

1.
Hosking J, Zoanetti D, Carlyle A, Anderson P, Costi D. Anesthesia for Treacher Collins syndrome: A review of airway management in 240 pediatric cases. Paediatr Anaesth 2012;22:752-8.  Back to cited text no. 1
    
2.
Goel L, Bennur SK, Jambhale S. Treacher-collins syndrome-a challenge for anaesthesiologists. Indian J Anaesth 2009;53:496-500.  Back to cited text no. 2
[PUBMED]  Medknow Journal  
3.
Bishop S, Clements P, Kale K, Tremlett MR. Use of glidescope ranger in the management of a child with Treacher Collin's syndrome in a developing world setting. Anesth Pain Manage 2009;19:695-6.  Back to cited text no. 3
    
4.
Kovac AL. Use of the Augustine stylet anticipating difficult tracheal intubation in Treacher-Collins syndrome. J Clin Anesth 1992;4:409-12.  Back to cited text no. 4
    
5.
Gharbaghian M. Difficult airway management in a patient with Treacher Collin syndrome with intubating LMA. Acta Med Iran 2006;44:281-4.  Back to cited text no. 5
    
6.
Muraika L, Heyman JS, Shevchenko Y. Fiberoptic tracheal intubation through a laryngeal mask airway in a child with Treacher Collins syndrome. Anesth Analg 2003;97:1298-9.  Back to cited text no. 6
    
7.
Waltl B, Melischek M, Schuschnig C, Kabon B, Erlacher W, Nasel C, et al. Tracheal intubation and cervical spine excursion: Direct laryngoscopy vs. intubating laryngeal mask. Anaesthesia 2001;56:221-6.  Back to cited text no. 7
    
8.
Heard CM, Caldicott LD, Fletcher JE, Selsby DS. Fiberoptic-guided endotracheal intubation via the laryngeal mask airway in pediatric patients: A report of a series of cases. Anesth Analg 1996;82:1287-9.  Back to cited text no. 8
    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
   Introduction
   Case Reports
   Discussion
   Conclusion
    References
    Article Figures

 Article Access Statistics
    Viewed1594    
    Printed17    
    Emailed0    
    PDF Downloaded365    
    Comments [Add]    

Recommend this journal