Background and Aims: Ventilator-associated pneumonia (VAP) is a major cause of morbidity and mortality among patients in the Intensive Care Units (ICUs) and results in added healthcare costs. One of the methods of preventing VAP is to use polyurethane (PU)-cuffed endotracheal tube (ETT). This study compares the incidence of VAP and length of ICU stay in patients intubated with conventional polyvinyl chloride (PVC) ETT and PU-cuffed ETT. Methods: Eighty post-laparotomy patients who were mechanically ventilated for >48 h in the ICU were included in this randomised controlled trial. Patients with moderate to severe pre-existing lung conditions were excluded from the study. Patients in group PVC (n = 40) were intubated with conventional PVC-cuffed ETT and those in group PU (n = 40) with PU-cuffed ETT. VAP was defined as a Clinical Pulmonary Infection Score of >6 with a positive quantitative endotracheal culture in patients on ventilator for >48 h. Results: Overall VAP rates were 23.75%. Thirteen (32.5%) patients in group PVC and six (15%) patients in group PU developed VAP. ICU stay was significantly lesser in patients intubated with PU-cuffed ETT (group PU) (median, 6 days; range: 4–8.5) compared to patients intubated with conventional ETT (group PVC) (median, 8; range: 6–11). Conclusion: No statistically significant reduction in the incidence of VAP could be found between the groups. The length of ICU stay was significantly lesser with the use of ultra thin PU-cuffed ETTs.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2771    
    Printed14    
    Emailed1    
    PDF Downloaded569    
    Comments [Add]    

Recommend this journal