Indian Journal of Anaesthesia  
About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions
Home | Login  | Users Online: 2669  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size    




 
 Table of Contents    
LETTER TO EDITOR
Year : 2017  |  Volume : 61  |  Issue : 10  |  Page : 851-852  

Pectoralis block for breast surgery: A surgical concern?


1 Department of Anaesthesiology, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India
2 Department of Breast Surgical Oncology, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra, India

Date of Web Publication12-Oct-2017

Correspondence Address:
Sumitra G Bakshi
Department of Anaesthesiology, Critical Care and Pain, Tata Memorial Hospital, Homi Bhabha National Institute, Mumbai, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_455_17

Rights and Permissions

How to cite this article:
Bakshi SG, Karan N, Parmar V. Pectoralis block for breast surgery: A surgical concern?. Indian J Anaesth 2017;61:851-2

How to cite this URL:
Bakshi SG, Karan N, Parmar V. Pectoralis block for breast surgery: A surgical concern?. Indian J Anaesth [serial online] 2017 [cited 2019 Dec 9];61:851-2. Available from: http://www.ijaweb.org/text.asp?2017/61/10/851/216674



Sir,

There is a growing interest in pectoral nerve blocks (PEC) for breast surgeries, as it provides reliable analgesia, without the potential risks of a neuraxial block.[1] We report an interesting intraoperative finding with the use of this block.

A 50-year-old woman was scheduled for right modified radical mastectomy. After premedication with fentanyl 100 μg and midazolam 2 mg, general anaesthesia was administered using propofol 50 mg and atracurium 25 mg, and the airway secured with a size 3 Supreme ®laryngeal mask. Under all aseptic precautions, ultrasound-guided 10 mL of local anesthetic (LA) [bupivacaine 25 mg plus lignocaine 100 mg] was administered between the pectoralis muscle (PEC I) planes and 20 mL of LA (bupivacaine 50 mg plus lignocaine 100 mg] was injected in the plane between the pectoralis minor and serratus anterior muscle, as described by Blanco (PECS II).[1] No haemodynamic or motor response to surgical incision was observed. During surgery, on reaching the axilla for axillary lymph node clearance, surgeons observed fluid beneath the fat plane [Figure 1]. In the presence of fluid, electrocautery (Coviden Force FX® Electrosurgical generator) failed to work at a current strength of 50 mA, and surgery was continued using scissors and surgical blade. Rest of the surgery was uneventful. In the post-operative period, the patient was pain-free and received a planned dose of oral paracetamol (1 gm) at the end of 6 h which was continued eight hourly. The worst pain score recorded in first 24 h, at movement, was <3/10.
Figure 1: Local anaesthetic accumulation (area marked) seen during axillary dissection, in a patient in whom pectoral nerve block was administered

Click here to view


We had similar experiences in other patients, who were administered the PECs block; fluid filled tissue planes were encountered during axillary tail dissection. The spread of dye along the tissue planes has been seen in previous radiological and cadaveric dissections which in fact explains the efficacy of the block.[1],[2] Inability to use the electro cautery during surgical dissection is the result of the local anaesthetic spread along the tissue planes.[3] In the presence of tissue oedema, tissue conductance increases and higher the conductance, lower is the resistance and results in reduced efficacy of the electrocautery. Increasing current strength of the electrocautery, changing over to bipolar cautery or harmonic scalpels, in such scenario, may help. The bipolar cautery, which works on the principle of closed loop is least affected by surrounding fluid.[3] The time of injection of PEC block prior to surgical dissection could influence our finding. The onset time of analgesia for PEC block is 3 min on an average.[1] In our case, the block was given after surgical preparation and draping; administering the block in the patient hold area would increase the interval between the block and surgical incision, and may alter the local anaesthetic absorption.

In conclusion, the spread of local anaesthetic along the fascial planes following PECS block could limit the use of electrocautery; the surgical team and the anaesthesiologist must be aware of the same.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Blanco R, Fajardo M, Parras Maldonado T. Ultrasound description of pecs II (modified pecs I): A novel approach to breast surgery. Rev Esp Anestesiol Reanim 2012;59:470-5.  Back to cited text no. 1
[PUBMED]    
2.
Mayes J, Davison E, Panahi P, Patten D, Eljelani F, Womack J, et al. An anatomical evaluation of the serratus plane block. Anesthesia 2016;71:1064-9.  Back to cited text no. 2
[PUBMED]    
3.
Sarkisian AM, Bernie AM, Lee R. Principles of electrocautery based techniques. In:, Chughtai B, Te AE, Kaplan SA. editors. Treatment of Benign Prostatic Hyperplasia: Modern Alternative to Transurethral Resection of the Prostate. New York: Springer Science + Business Media; 2015. p. 3-6.  Back to cited text no. 3
    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed1450    
    Printed3    
    Emailed0    
    PDF Downloaded301    
    Comments [Add]    

Recommend this journal