Indian Journal of Anaesthesia  
About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions
Home | Login  | Users Online: 1310  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size    


ORIGINAL ARTICLE
Year : 2017  |  Volume : 61  |  Issue : 5  |  Page : 393-397

Difficulty in inserting left double-lumen endobronchial tubes at the cricoid level in small-statured women: A retrospective study


1 Department of Anaesthesiology, Community Health Care Organization, Kyushu Hospital, Fukuoka, Japan
2 Department of Anaesthesia, Community Health Care Organization, Kyushu Hospital, Fukuoka, Japan

Correspondence Address:
Kenji Kayashima
Department of Anaesthesia, Japan Community Health Care Organization, Kyushu Hospital, 1-8-1 Kishinoura, Yahatanishi-ku, Kitakyushu, Fukuoka
Japan
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_13_17

Rights and Permissions

Background and Aims: Left double-lumen endobronchial tube (DLT) sizes are selected using tracheal diameters and left mainstem bronchial diameters (LMBDs) determined from chest radiographs or computed tomography (CT) scans. In Western women, 35-Fr or 37-Fr DLTs are often selected. However, difficulties can be encountered when inserting 32-Fr or 35-Fr DLTs in Japanese women. We investigated success rates for 32-Fr or 35-Fr DLT insertion in Japanese women and determined the causes of unsuccessful DLT insertion. Methods: We searched anaesthesia records of Japanese women aged ≥20 years who underwent thoracic surgery with 32-Fr or 35-Fr DLTs between April 2010 and March 2015 in our hospital. In the successful group (SG), patients were intubated using the initially selected DLTs. By contrast, in the unsuccessful group (UG), the DLT size had to be changed. The Mann–Whitney U-test and Fisher's exact test were used to compare groups. Results: The SG included 149 (96.1%) of 155 cases of 32-Fr DLT use and 119 (95.2%) of 125 cases of 35-Fr DLT use. Patient height was significantly lower in the UG than in the SG for the 35-Fr DLT (P = 0.0036). In seven of 12 UG patients (three for 32-Fr and four for 35-Fr), the transverse diameters of cricoid cartilages were smaller than the DLTs' tracheal diameters, thereby preventing passage through the cricoid cartilages. Conclusion: Along with LMBDs, transverse diameters of cricoid cartilages based on CT scans or ultrasonogram findings may help in selecting the appropriate left DLT size.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed452    
    Printed9    
    Emailed0    
    PDF Downloaded116    
    Comments [Add]    

Recommend this journal