Indian Journal of Anaesthesia  
About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions
Home | Login  | Users Online: 1884  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size    


ORIGINAL ARTICLE
Year : 2017  |  Volume : 61  |  Issue : 6  |  Page : 490-493

Comparison of efficacy and cost-effectiveness of 0.55% ortho-phthalaldehyde and 2% glutaraldehyde for disinfection of laryngoscopes: A prospective pilot study


1 Department of Anesthesiology, Seth G. S. Medical College, K.E.M. Hospital, Mumbai, Maharashtra, India
2 Department of Microbiology, Seth G. S. Medical College, K.E.M. Hospital, Mumbai, Maharashtra, India

Correspondence Address:
Priyanka Pradeep Karnik
B-404, Om Deep Sai Pooja CHS, Dr. Lazarus Road, Charai Naka, Thane. (West) - 400 602, Mumbai, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_22_17

Rights and Permissions

Background and Aims: The laryngoscope is a potential source of cross-infection as it involves contact with the mucous membrane, saliva and occasionally blood. This study compared efficacy and cost-effectiveness of two Centre for Disease Control approved agents for disinfection of laryngoscope blades. Methods: One hundred and sixty patients requiring laryngoscopy and intubation for general anaesthesia were randomly allocated into two groups. After tracheal intubation, used laryngoscope blades were cleaned with tap water. The blades were then immersed in either 2% w/v glutaraldehyde for a contact time of 20 min or 0.55% w/v ortho-phthalaldehyde (OPA) for 10 min. The handles were wiped with 0.5% w/v chlorhexidine wipes. Samples were collected using sterile cotton swabs from the tip, flange and light bulb area of the laryngoscope blade and one from the handle. They were cultured aerobically on blood and McConkey agar. Results: In 2% glutaraldehyde group, of 240 samples sent from the blades, 2 (0.8%) showed the growth of methicillin-resistant coagulase-negative staphylococci (MRCONS) and Enterobacter. In OPA group, of 240 samples, 2 (0.8%) showed growth of MRCONS. Thus, 2% glutaraldehyde and 0.55% OPA were comparable in terms of efficacy of disinfection. Growth was seen on 4 out of 160 handles. Conclusions: We suggest OPA for high-level disinfection of laryngoscope blades as it is equally efficacious as compared to glutaraldehyde, with a shorter contact time and available as a ready to use formulation.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1305    
    Printed13    
    Emailed0    
    PDF Downloaded222    
    Comments [Add]    

Recommend this journal