ORIGINAL ARTICLE
Year : 2018  |  Volume : 62  |  Issue : 4  |  Page : 269-279  

Current practice patterns of supraglottic airway device usage in paediatric patients amongst anaesthesiologists: A nationwide survey


Department of Anaesthesiology, Lokmanya Tilak Municipal General Hospital, Lokmanya Tilak Municipal Medical College, Mumbai, Maharashtra, India

Date of Web Publication11-Apr-2018

Correspondence Address:
Dr. Devangi A Parikh
Department of Anaesthesiology, Lokmanya Tilak Municipal General Hospital, Lokmanya Tilak Municipal Medical College, Sion, Mumbai - 400 022, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_65_18

Rights and Permissions
 


Background and Aims: Supraglottic airway devices (SGADs) are increasingly being used for airway management in paediatric patients undergoing general anaesthesia. This survey was designed to assess the nationwide practice patterns of SGAD usage in paediatric patients. Methods: A questionnaire of 28 questions was circulated amongst 16,532 members of the Indian Society of Anaesthesiologists through online survey engine Google Forms® and served manually to 500 delegates attending the Asian Society of Paediatric Anaesthesiologists conference 2017. Percentage, mean and standard deviation were calculated using Microsoft Excel 2016 (Redmond, WA, USA). Results: Four hundred and five (2.3%) valid responses were obtained. The most commonly used device was i-gel© (60.74%). Three hundred and four (75.06%) respondents had access to second-generation SGADs. Second-generation devices (60.74%) were more commonly used than first-generation devices (39.26%). Anaesthesiologists utilised SGADs in various challenging scenarios such as in the difficult airway (53.33%), remote locations (55.47%), ophthalmologic (38.77%) and long-duration surgeries (17.53%). Sixty per cent respondents did not use SGADs in laparoscopic surgery. Disposable SGADs were reused by 77.28% respondents. Oropharyngeal seal and intracuff pressures were not measured by 86.91% and 56.92% respondents, respectively. Difficulty in size selection (84.19%), securing position (82.22%) and maintaining unobstructed ventilation (78.76%) were common problems encountered while using SGADs. Conclusion: Although there is a widespread use of second-generation SGADs in Indian paediatric anaesthesia, safe practices such as using capnography, measurement of oropharyngeal seal pressure, cuff pressure and appropriate disinfection are lacking.

Keywords: Airway management, disinfection, laryngeal masks, paediatric anaesthesia, supraglottic airway device, survey


How to cite this article:
Jain RA, Parikh DA, Malde AD, Balasubramanium B. Current practice patterns of supraglottic airway device usage in paediatric patients amongst anaesthesiologists: A nationwide survey. Indian J Anaesth 2018;62:269-79

How to cite this URL:
Jain RA, Parikh DA, Malde AD, Balasubramanium B. Current practice patterns of supraglottic airway device usage in paediatric patients amongst anaesthesiologists: A nationwide survey. Indian J Anaesth [serial online] 2018 [cited 2018 Oct 20];62:269-79. Available from: http://www.ijaweb.org/text.asp?2018/62/4/269/229805




   Introduction Top


Supraglottic airway devices (SGADs) are routinely used for airway management in paediatric patients undergoing general anaesthesia for various surgeries. SGADs have changed the practice of paediatric anaesthesia.[1],[2],[3] The newer SGADs have improved features such as the gastric drain tube, better ventilation and seal pressures, and an ability to perform an endotracheal intubation through them. SGADs with a gastric drain tube are classified as second-generation SGADs and are promoted for routine use by Royal College of Anaesthetists in the National Audit Project 4.[4]

Although newer SGADs are freely available for commercial use, there is a dearth of high-quality studies to establish their safety in children.[5] There are studies and case reports in literature describing SGAD use in uncommon and unconventional situations such as laparoscopy and prone position in paediatric patients.[6],[7] It would be worthwhile to know if these practices are being applied in clinical use. In the absence of high-quality evidence, there could be a possibility of bias for or against newer devices. A good quality survey may shed some more light on the practices associated with SGADs, identify problems which may have not been reported and bridge the lacunae in the existing literature.

The aim of this survey was to get an overview of SGAD usage in paediatric patients in terms of knowledge, attitudes and practice patterns of anaesthesiologists in India. The objectives were to find out (1) the choice of SGAD in routine use and reasoning behind the choice; (2) anaesthesia practices associated with SGAD use; (3) use of SGAD in complicated and uncommon situations; (4) use of SGAD in difficult airway; (5) safety measures followed while using SGADs and (6) desirable newer design features involving SGADs in paediatric patients.


   Methods Top


The instrumentation type of survey methodology was used. A questionnaire was prepared by doing a thorough literature search on web-based electronic databases such as PubMed, Google Scholar and Embase. The keywords used were paediatric, practice patterns, SGADs, laryngeal mask airways and extraglottic airway devices. Forty questions were prepared. In addition, 20 questions were added by the investigators based on their experience and problems encountered in clinical practice. All the questions were thoroughly analysed and 49 questions were shortlisted. The first version of the questionnaire was then mailed to thirty expert paediatric anaesthesiologists. Ten experts responded. They were asked to rate the relevance of every question on a 4-point scale (1 = not relevant, 2 = somewhat relevant, 3 = relevant and 4 = highly relevant). Item content validity index (ICVI) for each question was calculated (ICVI = number of experts rating questions as 3–4 divided by a total number of experts). The questions with ICVI >0.78 were retained in the second version (n = 35).[8] Scale content validity index (SCVI) (SCVI = Total of ICVI scores divided by the total number of included questions) of second version of questionnaire was 0.97 which was within acceptable limits.[8] This second questionnaire with 35 questions was circulated amongst anaesthesiologists of our teaching institute for checking feasibility. In the final version, 28 questions were retained. Ethics Committee approval was obtained. The survey was registered with Clinical Trials Registry of India (CTRI REF/2018/02/017539).

The questionnaire [Appendix 1], [Additional file 1] prepared in English, included basic demographic data such as age, state of residence, qualification, current affiliation, position in institute, years of experience, type of practice and average number of paediatric cases in a month. Twenty-seven questions had multiple choice answers and participants could tick one or more answers depending on the question. The participants had to rate design features on a scale of 1–5 in the last question. The questionnaire had six parts. Question numbers 1–6 included overview and choice of SGAD, questions 7–9 covered current anaesthesia practices associated with SGAD use, questions 10–16 comprised the use of SGAD in uncommon and complicated situations, questions 17 and 18 enquired about the usage of SGADs in difficult airway, questions 19–27 included safety measures associated with their use and question 28 sought personal opinion on design of SGAD.

The questionnaire was manually distributed to the 500 delegates of the Asian Society of Paediatric Anaesthesiologists Conference 2017, at Mumbai. E-mails were also sent to 16,532 members of the Indian Society of Anaesthesiologists from 15/7/17 to 15/9/17. E-mails were not sent to those who had manually filled the forms. Two E-mail reminders were sent to those who did not respond. Participants were requested to fill the questionnaire only once. Completion and submission of questionnaire by the respondents implied consent. Responses received till 30/09/17 were analysed.

All analyses were performed using Microsoft Excel 2016 (Redmond, WA, USA). Sample size was calculated using online calculator from 'The survey system 2016, Creative research systems, Sebastopol, California'. For an estimated population of 17,000, the sample size was calculated to be 376 for a margin of error of 5% and 95% confidence interval.


   Results Top


Five hundred and seven anaesthesiologists responded to the survey. We excluded the responses of postgraduate students (59), of those who practiced outside India (15) and of those who did not use SGADs in paediatric patients (34). Six responses fit two or more above-mentioned exclusion criteria, so they were excluded only once. Four hundred and five valid responses (370 online and 35 manual) were analysed. The demographic details of the respondents are presented in [Table 1]. In question numbers 3, 6, 8 and 18, multiple responses were allowed and the sum of responses does not add up to 405 and the percentages do not add up to 100.
Table 1: Demographic profile of survey respondents

Click here to view


The various SGADs used by respondents are summarised in [Table 2]. The most commonly used device was i-gel © (n = 246, 60.74%) followed by LMA classic © (cLMA) reusable (n = 240, 59.26%). Three hundred and four (75.06%) respondents had access to second-generation SGADs. Second-generation devices (n = 246, 60.74%) were more commonly used than first-generation devices (n = 159, 39.26%). The order of preference of first-generation devices (n = 159) was: cLMA © reusable – 111 (69.8%), cLMA © disposable – 30 (18.87%), Ambu Aura i © – 12 (7.54%), Soft Seal Laryngeal Mask © – 3 (1.89%), LMA Flex © – 2 (1.26%) and Ambu Aura 40© 1 (0.63%). The order of preference of second-generation devices (n = 246) was i-gel © – 149 (60.57%), LMA ProSeal © – 60 (24.39%), LMA Supreme © – 24 (9.76%), Ambu AuraGain © – 12 (4.88%) and Laryngeal Tube Suction © (LTS) – 1 (0.40%). Past experience – 277 (68.4%), evidence from research – 133 (32.8%), cost – 120 (29.6%), hospital or department recommendation – 80 (19.75%) and reusability – 64 (15.80%), whatever is given to them – 48 (11.85%), availability – 9 (2.22%) and others – 4 (0.98%) were the factors which influenced the choice of respondents while using any SGAD.
Table 2: Types of various supraglottic airway devices used by respondents

Click here to view


The maximum duration of surgery for which respondents would use SGAD was < 30 min – 37 (9.14%), 30–60 min – 175 (43.21), >60–90 min – 122 (30.12%) and >90 min – 71 (17.53%). Spontaneous ventilation was used by 274 (67.65%) respondents. Manual ventilation using the Jackson Rees circuit or Bain's circuit was the next most common practice (n = 183, 45.19%). Pressure control (n = 127, 31.36%), volume control (n = 107, 26.42%) and pressure support ventilation (n = 87, 21.48%) were the other modes of ventilation used. Similar number of respondents preferred removing the SGAD in deep plane of anaesthesia (n = 202) and awake state (n = 203).

The responses about the use of SGAD in uncommon and complicated clinical situations are summarised in [Table 3]. Of the 400 respondents who do paediatric laparoscopic surgical cases, 243 (60.75%) never used, whereas 66 (16.5%) used sometimes, 62 (15.5%) rarely, 26 (6.5%) almost always and 3 (0.75%) always used SGAD for laparoscopic surgeries. Amongst those who do cases in remote locations (n = 323), 179 (55.42%) used SGADs. All respondents were comfortable while using SGAD in supine position but fewer used it in lithotomy (n = 209, 51.60%), lateral (n = 198, 48.89%) and prone position (n = 9, 2.22%).
Table 3: Supraglottic airway device use in different situations

Click here to view


Two hundred and sixteen (53.33%) respondents had used a SGAD in a known difficult airway. The devices used by respondents in a known difficult airway were i-gel © – 83 (38.43%), cLMA © – 66 (30.56%), LMA ProSeal © – 32 (14.81%), Ambu AuraGain © – 11 (5.09%), LMA Supreme © – 10 (4.63%), Ambu Aura-i © – 16 (7.41%), LMA Flex © – 6 (2.78%), air-Q © – 4 (1.85%), Intubating LMA © – 3 (1.39%), LTS © – 2 (0.93%) and Ambu Aura 40© – 1 (0.46%). Eighty-six respondents (21.23%) had intubated through a SGAD at least once. SGAD was used as an intubation conduit by 33 (8.15%) in normal airways, 67 (16.54%) in a known difficult airway and 24 (5.92%) in unanticipated difficult airway. Fibre-optic bronchoscope (FOB), bougie/introducer-guided and blind technique were used by 33 (8.14%), 39 (9.62%) and 28 (6.91%), respectively.

The complications faced by respondents are mentioned in [Table 4]. Capnometer was used always by 316 (78.02%) respondents, while it was used sometimes or never by 70 (17.28%) and 12 (2.96%), respectively. The rest (7 [1.73%]) did not have access to capnometer.
Table 4: Frequency of complications faced by respondents

Click here to view


When a cuffed SGAD was used (n = 390), 43 (11.03%) measured the intracuff pressure always, 125 (32.05%) measured it sometimes and 116 (29.74%) did not measure it at all. Equipment needed to measure intracuff pressures was not available to 106 (27.18%). Gradual inflation of the cuff till there is no leak, but up to the maximum recommended volume, was practiced by 234 (60%) respondents, while 97 (24.87%) inflated with the maximum and 24 (6.15%) with half the recommended volume. Cuff pressure monitor to guide the inflation of the cuff was used by 35 (8.98%) respondents. The vast majority of the respondents (n = 352, 86.91%) did not measure seal pressures. Seal pressure was measured for every case by 53 (13.09%) of respondents only. Only 33 (8.15%) respondents measured it again after change in position of patients.

Disposable and reusable devices were preferred by 46 (11.36%) and 132 (32.59%), respectively, while 227 (56.05%) respondents have no such preference. Disposable SGADs were reused by 313 (77.28%) respondents. Amongst these, 157 (50.16%) reused the SGAD till it is no longer usable while rest reused it up to 10 times. Various techniques of disinfection used are mentioned in [Table 5]. The ratings given for various desirable design features in SGADs are highlighted in [Table 6].
Table 5: Various methods of disinfection of disposable supraglottic airway devices

Click here to view
Table 6: Rating given to various design features in supraglottic airway devices

Click here to view



   Discussion Top


This survey provides an insight into the practice patterns of anaesthesiologists working in India, while using SGADs in paediatric patients. Surveys have been conducted by the Society of Pediatric Anesthesia (SPA) and Association of Paediatric Anaesthetists of Great Britain and Ireland (AAGBI).[5],[9] However, there is a dearth of comprehensive large-scale pan-Indian data.[10] AAGBI survey focussed mainly on the choice of SGADs and their use in difficult airway. SPA survey concentrated mainly on practice patterns pertaining to LMA family. Unlike SPA survey, we asked 'have you used' instead of 'would you use' to elicit practice patterns and eliminate theoretical responses. The only survey conducted in India focussed on few practice patterns.[10] We aimed to develop a comprehensive validated questionnaire covering choice, practice patterns in a variety of situations, safety measures employed and desirable newer design features involving SGADs in paediatric patients.

A wide variety of second-generation SGADs are now available in paediatric sizes [1],[11] making their use quite common in India. This is significantly different from the findings of older surveys where first-generation devices were used more often.[5],[10] The extensive use of i-gel © and cLMA © is perhaps due to ease of use and low rate of serious complications.[3],[11] A single point survey involving delegates of national paediatric conference in 2016 found cLMA © to be most popular.[10] Our nationwide survey conducted 1½ years later has shown i-gel © as the most commonly used device. This may represent a shift in the preference of Indian anaesthesiologists. Past experience, rather than evidence from research, guides the choice while selecting a particular SGAD, which is similar to survey conducted by AAGBI.[5]

Controlled ventilation and pressure support ventilation have been shown to be superior to spontaneous ventilation with ProSeal LMA ©.[12],[13],[14] Spontaneous ventilation or controlled ventilation using Bain's or Jackson Rees circuit was the most commonly used method of ventilation while using SGAD amongst our respondents. This is in contrast to the SPA survey where pressure support ventilation was used by a large number of respondents.[9] Lack of sophisticated anaesthesia ventilators, knowledge and experience in using advanced modes could explain this difference. Advanced modes improve ventilation parameters, thereby enabling anaesthesiologists to use SGADs for prolonged duration.[10] This also explains the reluctance that our respondents had in using SGADs in surgeries lasting for >90 min, unlike the SPA survey.

A greater percentage (28.15%) of our respondents and those from previous Indian survey (38%) do not use SGADs in infants which is in contrast to SPA survey where 9% respondents would not use at all.[9],[10] This could be attributed to the late introduction of very small SGADs in the Indian market. Majority of our respondents also did not use SGADs in neonates or used them only sometimes. This reluctance to use SGADs in younger patients could be due to the differences in airway anatomy of such patients causing suboptimal placement, thereby requiring frequent repositioning.[15]

The use of SGAD in ophthalmological surgery is high like previous survey.[9] Although the efficacy of second-generation SGADs in paediatric laparoscopic surgeries is reported,[6],[16] majority of our respondents were uncomfortable with their use. However, SGADs have made an inroad into practice with around 7.25% respondents using it almost always or always during laparoscopy like the respondents of SPA survey.[9] SGADs do not appear to be a choice of airway management for tonsillectomies for most respondents. Small studies have shown SGADs to be a suitable alternative to endotracheal intubation,[17],[18] but a larger study reveals higher incidence of complications, mainly airway obstruction.[19] Appropriate patient selection, careful insertion, spontaneous ventilation and experience may decrease the incidence of complications. Very few respondents are comfortable with the use of SGAD in prone position like in the SPA survey.[9] Prone positioning limits access to the airway and can pose a dangerous situation if SGAD is malpositioned. The demand for anaesthetising paediatric patients in remote locations such as radiology suites is rising, and it is encouraging to know that SGADs are commonly used by our respondents and this is also being reported in literature.[20],[21]

SGADs are now an integral part of paediatric difficult airway algorithms and guidelines [22],[23] and more than half of the respondents have used SGADs in a child with a known difficult airway. i-gel © and cLMA © were the most commonly used devices. Use of introducers and FOB through a SGAD serve as facilitators for intubation.[24] SPA and AAGBI surveys have only assessed fibre-optic intubation through SGAD, whereas we incorporated the blind/introducer-guided technique in our questionnaire.[5],[9] More than 50% respondents in AAGBI survey had performed FOB-assisted intubation through SGAD in contrast to India where only 9% had done the same. A significant number of our respondents used the blind technique indicating lack of availability of paediatric size FOB.

Current studies tell us more about efficacy rather than safety of SGADs.[25] Aspiration is the most common complication reported in the NAP4.[4] However, in this survey, we found that difficulty in size selection was the most common problem, followed by difficulty in securing position and maintaining unobstructed ventilation. This is similar to previous surveys.[5],[10] Here lies the importance of survey where day-to-day difficulties encountered during routine practice get highlighted. However, surveys have limitations as the incidence of rare complications may not get reflected.

Capnography is essential at all times as per the American Society of Anesthesiologists' minimum monitoring standards.[26] General anaesthesia causes significant alterations in respiratory mechanics of paediatric patients. This causes a gradual rise in end-tidal carbon dioxide even though the child is breathing spontaneously. However, nearly a quarter of respondents did not always use a capnometer along with SGADs. This could probably be due to a reluctance to attach a heavy mainstream capnometer adapter to a small SGAD, unavailability, or ignorance of its benefit for short duration procedures. This safety issue has not been addressed in previous surveys.

Very few respondents used a cuff pressure manometer while inflating the cuff of SGADs. Lack of equipment or knowledge could be the probable cause. Using clinical end points to inflate LMA cuffs is associated with significant hyperinflation and may lead to loss of seal between larynx and oesophagus. When cuff pressure exceeds mucosal perfusion pressure, complications such as sore throat and nerve injuries occur.[1] Very young patients are not able to communicate these problems and they may become irritable in the post-operative period. Therefore, cuff manometers should routinely be used.[27]

Measurement of oropharyngeal seal pressure quantifies the efficacy of the seal and ensures optimum ventilation. It also reduces leaks into the oesophagus, thereby reducing the risk of regurgitation and aspiration.[1] Experts have recommended that oropharyngeal seal pressure should be assessed routinely and also rechecked with every change of patient position.[1] Yet, a majority of respondents did not measure the seal pressure at all. Lack of emphasis given during training could possibly be the reason why these important safety practices are seldom used. Moreover, these important issues have not been covered in the previous surveys.

The current survey found that there is widespread reuse of disposable SGADs. This is similar to a survey conducted on SGADs in adults in India.[28] This could be due to its initial easy availability at low cost. Rampant reusing indicates a compulsion of keeping costs low in a limited-resource country. The techniques used for disinfection also varied widely amongst respondents and were largely inadequate for semi-critical equipment such as SGADs which require high-level disinfection.[29] Such practices may predispose the patient to infection, and the oropharyngeal seal of the SGAD may also be lost due to damage caused by repeated reuse.

Novel design features such as in-built cuff pressure monitor and devices allowing higher ventilation pressures have found lower rating in this survey, mainly because of lack of importance given to cuff and oropharyngeal seal pressures in routine practice or an associated increase in cost. It is interesting that the sought-after feature is a design allowing use as an easy conduit for intubation, highlighting the importance of SGAD in a difficult airway.[23]

The poor response rate of the survey could be due to the highly selective field of study, i.e., supraglottic devices in paediatric patients. Furthermore, the responses of predominantly urban anaesthesiologists may not necessarily reflect the practice patterns across the country.


   Conclusion Top


Second-generation SGADs are increasingly being used by anaesthesiologists across India in varied situations, representing a paradigm shift in the approach towards airway management in paediatric patients. However, techniques to improve safety, i.e., intracuff and seal pressure measurement, use of capnography and appropriate disinfection techniques are lacking which needs to be emphasised during training and continued medical education.

Acknowledgements

We sincerely thank all the experts for spending their valuable time and validating the survey questionnaire: Children's Anaesthesia Services, Mumbai, Dr. Ashwin Udupa, Dr. Chandrika Y. R., Dr. Diganta Saikia, Dr. Dilip Pawar, Dr. Jeson Doctor, Dr. Nandini Dave, Dr. Rakhee Goyal, Dr. Sandhya Yaddanapudi, Dr. S. Ramesh, Dr. Snehalata Dhaygude and Dr. Vibhavari Naik.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Goyal R. Small is the new big: An overview of newer supraglottic airways for children. J Anaesthesiol Clin Pharmacol 2015;31:440-9.  Back to cited text no. 1
[PUBMED]  [Full text]  
2.
Ramesh S, Jayanthi R. Supraglottic airway devices in children. Indian J Anaesth 2011;55:476-82.  Back to cited text no. 2
[PUBMED]  [Full text]  
3.
White MC, Cook TM, Stoddart PA. A critique of elective pediatric supraglottic airway devices. Paediatr Anaesth 2009;19 Suppl 1:55-65.  Back to cited text no. 3
    
4.
Cook T, Woodall N, Frerk C. Major Complications of Airway Management in the United Kingdom. 4th National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Reports and Findings; 2011. p. 86-95.  Back to cited text no. 4
    
5.
Bradley AE, White MC, Engelhardt T, Bayley G, Beringer RM. Current UK practice of pediatric supraglottic airway devices – A survey of members of the Association of Paediatric Anaesthetists of Great Britain and Ireland. Paediatr Anaesth 2013;23:1006-9.  Back to cited text no. 5
    
6.
Sinha A, Sharma B, Sood J. ProSeal as an alternative to endotracheal intubation in pediatric laparoscopy. Paediatr Anaesth 2007;17:327-32.  Back to cited text no. 6
    
7.
Taxak S, Gopinath A. Insertion of the i-gel airway in prone position. Minerva Anestesiol 2010;76:381.  Back to cited text no. 7
    
8.
Polit DF, Beck CT. The content validity index: Are you sure you know what's being reported? Critique and recommendations. Res Nurs Health 2006;29:489-97.  Back to cited text no. 8
    
9.
Patel A, Clark SR, Schiffmiller M, Schoenberg C, Tewfik G. A survey of practice patterns in the use of laryngeal mask by pediatric anesthesiologists. Paediatr Anaesth 2015;25:1127-31.  Back to cited text no. 9
    
10.
Kaniyil S, Smithamol PB, Joseph E, Krishnadas A, Ramadas KT. A survey of current practice of supraglottic airway devices in pediatric anesthesia from India. Anesth Essays Res 2017;11:578-82.  Back to cited text no. 10
[PUBMED]  [Full text]  
11.
Jagannathan N, Ramsey MA, White MC, Sohn L. An update on newer pediatric supraglottic airways with recommendations for clinical use. Paediatr Anaesth 2015;25:334-45.  Back to cited text no. 11
    
12.
Templeton TW, Hoke LK, Templeton LB, Ririe DG, Rose DM, Bryan YF, et al. Acomparison of 3 ventilation strategies in children younger than 1 year using a Proseal laryngeal mask airway: A randomized controlled trial. J Clin Anesth 2016;35:502-8.  Back to cited text no. 12
    
13.
Templeton TW, Hoke LK, Yaung J, Aschenbrenner CA, Rose DM, Templeton LB, et al. Comparing 3 ventilation modalities by measuring several respiratory parameters using the ProSeal laryngeal mask airway in children. J Clin Anesth 2016;34:272-8.  Back to cited text no. 13
    
14.
Lim B, Pawar D, Ng O. Pressure support ventilation vs. spontaneous ventilation via ProSeal™ laryngeal mask airway in pediatric patients undergoing ambulatory surgery: A randomized controlled trial. Paediatr Anaesth 2012;22:360-4.  Back to cited text no. 14
    
15.
Von Ungern-Sternberg BS, Wallace CJ, Sticks S, Erb TO, Chambers NA. Fibreoptic assessment of paediatric sized laryngeal mask airways. Anaesth Intensive Care 2010;38:50-4.  Back to cited text no. 15
    
16.
Tulgar S, Boga I, Cakiroglu B, Thomas DT. Short-lasting pediatric laparoscopic surgery: Are muscle relaxants necessary? Endotracheal intubation vs. laryngeal mask airway. J Pediatr Surg 2017;52:1705-10.  Back to cited text no. 16
    
17.
Sierpina DI, Chaudhary H, Walner DL, Villines D, Schneider K, Lowenthal M, et al. Laryngeal mask airway versus endotracheal tube in pediatric adenotonsillectomy. Laryngoscope 2012;122:429-35.  Back to cited text no. 17
    
18.
Peng A, Dodson KM, Thacker LR, Kierce J, Shapiro J, Baldassari CM, et al. Use of laryngeal mask airway in pediatric adenotonsillectomy. Arch Otolaryngol Head Neck Surg 2011;137:42-6.  Back to cited text no. 18
    
19.
Lalwani K, Richins S, Aliason I, Milczuk H, Fu R. The laryngeal mask airway for pediatric adenotonsillectomy: Predictors of failure and complications. Int J Pediatr Otorhinolaryngol 2013;77:25-8.  Back to cited text no. 19
    
20.
Ucisik-Keser FE, Chi TL, Hamid Y, Dinh A, Chang E, Ferson DZ, et al. Impact of airway management strategies on magnetic resonance image quality. Br J Anaesth 2016;117 Suppl 1:i97-i102.  Back to cited text no. 20
    
21.
Zaballos M, Bastida E, del Castillo T, de Villoria JG, Jiménez C.In vitro study of magnetic resonance imaging artefacts of six supraglottic airway devices. Anaesthesia 2010;65:569-72.  Back to cited text no. 21
    
22.
Weiss M, Engelhardt T. Proposal for the management of the unexpected difficult pediatric airway. Paediatr Anaesth 2010;20:454-64.  Back to cited text no. 22
    
23.
Pawar DK, Doctor JR, Raveendra US, Ramesh S, Shetty SR, Divatia JV, et al. All India difficult airway association 2016 guidelines for the management of unanticipated difficult tracheal intubation in paediatrics. Indian J Anaesth 2016;60:906-14.  Back to cited text no. 23
[PUBMED]  [Full text]  
24.
Wong DT, Yang JJ, Mak HY, Jagannathan N. Use of intubation introducers through a supraglottic airway to facilitate tracheal intubation: A brief review. Can J Anaesth 2012;59:704-15.  Back to cited text no. 24
    
25.
Cook TM, Kelly FE. Time to abandon the 'vintage' laryngeal mask airway and adopt second-generation supraglottic airway devices as first choice. Br J Anaesth 2015;115:497-9.  Back to cited text no. 25
    
26.
Standards for Basic Anesthetic Monitoring – American Society of Anesthesiologists. American Society of Anesthesiologists; 2015. Available from: http://www.asahq.org/quality-and-practice-management/practice-guidance-resource-documents/standards-for-basic-anesthetic-monitoring. [Last accessed on 2017 Nov 22].  Back to cited text no. 26
    
27.
Licina A, Chambers NA, Hullett B, Erb TO, von Ungern-Sternberg BS. Lower cuff pressures improve the seal of pediatric laryngeal mask airways. Paediatr Anaesth 2008;18:952-6.  Back to cited text no. 27
    
28.
Kadar SM, Koshy R. Survey of supraglottic airway devices usage in anaesthetic practice in South Indian state. Indian J Anaesth 2015;59:190-3.  Back to cited text no. 28
    
29.
Rutala WA, Weber DJ. Healthcare Infection Control Practices Advisory Committee (HICPAC). Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008. Atlanta: Centers for Disease Control and Prevention; 2008. Available from: http://www.cdc.gov/hicpac/pdf/guidelines/disinfection_nov_2008.pdf. [Last accessed on 2018 Jan 22].  Back to cited text no. 29
    



 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5], [Table 6]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Methods
   Results
   Discussion
   Conclusion
    References
    Article Tables

 Article Access Statistics
    Viewed861    
    Printed17    
    Emailed0    
    PDF Downloaded255    
    Comments [Add]    

Recommend this journal