Multimodal temperature management during donor hepatectomy under combined general anaesthesia and neuraxial analgesia: Retrospective analysis


1 Department of Anaesthesiology, Institute of Liver and Biliary Sciences, New Delhi, India
2 Department of Research, Institute of Liver and Biliary Sciences, New Delhi, India

Correspondence Address:
Dr. Manish Tandon
Department of Anaesthesia, Institute of Liver and Biliary Sciences, D-1, Vasant Kunj, New Delhi
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_123_18

Rights and Permissions

Background and Aims: Unintended hypothermia (UIH) during surgery under general anaesthesia has adverse implications. A retrospective analysis of the perioperative temperature records of healthy voluntary liver donors was done to evaluate the efficacy of a multimodal protocol for temperature management. Methods: Records of 50 American Society of Anesthesiologists physical status Class 1 patients operated for Donor Hepatectomy lasting >2 h under combined general and epidural anaesthesia were analysed. Ambient temperature was maintained 24°C–27°C before induction of GA and during insertion of epidural catheter. Active warming was done using warming mattress set to temperature 38°C, hot air blanket with temperature set to 38°C and fluid warming device (Hotline™) with preset temperature of 41°C. Nasopharyngeal temperature was continuously monitored. After induction of GA and draping of the patient, ambient temperature was decreased and maintained at 21°C–24°C and was again increased to 24°C–27°C at the conclusion of surgery. During surgery, for every 0.1°C above 37°C, one heating device was switched off such that at 37.3°C all the 3 devices were switched off. Irrigation fluid was pre-warmed to 39°C. Results: Baseline temperature was 35.9°C ± 0.4°C. Minimum temperature recorded was 35.7°C ± 0.4°C. Mean decrease in temperature below the baseline temperature was 0.2°C ± 0.2°C. Temperature at the end of surgery was 37.4°C ± 0.5°C. Conclusion: Protocol-based temperature management with simultaneous use of resistive heating mattress, forced-air warming blanket, and fluid warmer along with ambient temperature management is an effective method to prevent unintended perioperative variation in body temperature.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed408    
    Printed16    
    Emailed0    
    PDF Downloaded137    
    Comments [Add]    

Recommend this journal