EDITORIAL
Year : 2019  |  Volume : 63  |  Issue : 2  |  Page : 81-83  

Intraoperative neurophysiologic monitoring and anaesthetic implications


Associate Professor, Division of Neuroanesthesia and Neurocritical Care, Incharge Neurosurgical ICU SKIMS Soura, Srinagar, Jammu and Kashmir, India

Date of Web Publication11-Feb-2019

Correspondence Address:
Zulfiqar Ali
Associate Professor, Division of Neuroanesthesia and Neurocritical Care, Incharge Neurosurgical ICU SKIMS Soura, Srinagar, Jammu and Kashmir
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_64_19

Rights and Permissions

How to cite this article:
Ali Z. Intraoperative neurophysiologic monitoring and anaesthetic implications. Indian J Anaesth 2019;63:81-3

How to cite this URL:
Ali Z. Intraoperative neurophysiologic monitoring and anaesthetic implications. Indian J Anaesth [serial online] 2019 [cited 2019 Feb 21];63:81-3. Available from: http://www.ijaweb.org/text.asp?2019/63/2/81/251977



It was in 1973 that the intraoperative wake-up test was described by Pierre Stagnara along with the anaesthesiologist Mme Vauzelle.[1] Over a period of 65 years, the intraoperative wake-up test has been replaced by intraoperative neurophysiologic monitoring, which has become a real-time monitor of the functional integrity of neural structures. If appropriate manoeuvres (such as correction of hypotension and hypoxia and timely decompression from surgical retractors, pressure from bony structures, or haematomas) are taken, there may be a reduction of the neurological ischaemia and decreased morbidity.[2]

Both sensory and motor evoked potentials (EPs) are used in the operating room to assist in the surgical decision making. In the operating room, both sensory evoked potentials (SEPs) and motor evoked potentials (MEPs) are used as surrogates for postoperative clinical endpoints of motor and sensory wellbeing, as their true endpoints (with the exception of the ''wake-up'' test or awake cranial surgeries) are not available in the operating room. Holdefer[3]et al. did a literature search to investigate the causal links between surgical events and EP changes. They found that although the monitoring of EPs was not fully validated, their continued use in the intraoperative period helps to avoid or reduce the neural injury.[3] The American Society of Neurophysiological Monitoring came out with a position statement that evoked potentials are an established practice option for cortical and subcortical mapping and for monitoring during surgeries that may cause injury to the brain, brainstem, spinal cord, or facial nerve.[4] During monitoring of somatosensory, visual, and brainstem auditory EPs, the specific stimulations are applied to the peripheral sites and the desired responses are recorded from the central locations. MEP monitoring for intraoperative monitoring requires transcranial stimulation of the motor cortex by electrical or magnetic means to produce a descending response that traverses the corticospinal tracts and eventually generates a measurable response. The desired recordings may be obtained from the epidural space (D-wave) or from the distal muscle.

The amplitude (measured in microvolts) is defined as the distance from the peak to adjacent trough. The time from the stimulation to the peak in milliseconds is defined as the latency. Loss of or change in the waveform can indicate the need for modification of surgical strategy, patient positioning, or patients physiological management in order to prevent or minimise neurologic injury. Specifically, a 50% reduction in amplitude or a 10% increase in latency of SSEPs, MEPs, and brain stem auditory evoked potentials (BAEPs) is considered to be of pathological significance.


   Anaesthetic Effects on Neuromonitoring Top


Most anaesthetic agents cause a dose-dependent depression in synaptic activity. It has been seen that all anaesthetic agents affect MEP muscle responses and cortical potentials. Inhalational agents affect the EPs to a greater extent than the intravenous (IV) anaesthetic agents.[5] The effects are much greater on cortical responses than on subcortical responses.[6],[7] Nitrous oxide (N2O) also causes a reduction in the amplitude and an increase in the latency of both cortical sensory responses and MEP when used alone or in combination with halogenated inhalational agents or opioids.[8] It has been observed that opioids cause mild depression of sensory and motor responses, with a loss of late sensory evoked response peaks (>100 msec) at doses, which cause sedation. Fentanyl, remifentanil, or sufentanil infusions are commonly used for TIVA to facilitate neuromonitoring. Koht et al.[9] observed the effects of etomidate, midazolam, and thiopental on median nerve somatosensory EPs. Etomidate increased both amplitude and latency. Thiopental decreased amplitude and increased latency, whereas midazolam had no effect on amplitude but increases the latency. Schubert and Licina[10] observed that ketamine enhanced the cortical SSEP and MEP amplitude and partially reversed the depressant effect of N2O on SSEPs. Hence, an anaesthetic regimen with induction of anaesthesia by ketamine (2 mg/kg IV) followed by continuous infusion at a rate of 30 mcg kg-1 min-1 may be desirable for neuromonitoring. Variable effects have been reported with dexmedetomidine during SSEP or MEP monitoring. Mahmoud et al. found that dexmedetomidine as an anaesthetic adjunct to propofol-based TIVA significantly attenuated the amplitude of transcranial electric MEPs.[11] However, Rozet et al. observed that there was no difference in SEPs (latency and amplitude) and MEPs (amplitude and latency) between dexmedetomidine versus placebo groups.[12]

A balanced anaesthesia approach may be followed using a low-dose inhalation anaesthetic agent (up to 0.5 MAC) and low to medium dose propofol (50 to 100 mcg kg-1 min-1 intravenously) with a relatively high-dose opioid (fentanyl, remifentanil). However, inadequate generation of EPs may need a modification of the anaesthetic techniques. There is still a paucity of ideal anaesthetic techniques, that can be utilised for the optimal generation of EPs.

Over the last few decades, there has been an increase in the number of centres using intraoperative neuromonitoring across India in an attempt to reduce the neurological morbidity. This issue of Indian Journal of Anaesthesia features two articles on intraoperative neuromonitoring.[13],[14] In a pursuit for an ideal anaesthetic technique for patients undergoing surgery for spinal cord tumours, Parthiban et al.[13] have made an attempt to study the effects of IV anaesthesia (propofol) and inhalational anaesthesia (isoflurane) on the intraoperative motor evoked potentials (iMEPs). Authors observed that propofol anaesthesia lead to the generation of more successful baseline iMEPs (74%) when compared with isoflurane anaesthesia (50%). In addition to the anaesthetic effects, the authors found interesting findings that age and duration of symptoms could have a significant influence on elicitation of baseline iMEP. These possible effects of aging may be a result of a decrease in nervous tissue mass, neuronal density, and concentrations of various neurotransmitters.[15],[16] In patients over 40 years under propofol anaesthesia, iMEP responses could be recorded in 60% of the muscles whereas under isoflurane group responses, it could be recorded in only 40% of the muscles. The correlation trend line shows that in patients with >12 months of duration of symptoms, 42% iMEP responses could be recorded under propofol anaesthesia whereas it is lesser under isoflurane (35%) anaesthesia. Lesser stimulus strength to elicit baseline iMEPs and less potential fading was observed with propofol as compared with isoflurane anaesthesia.

Before interpreting the changes in EP during intraoperative neurophysiological monitoring, physiological factors such as hypoxia, hypotension, hypothermia, and anaemia should be corrected. Positional changes as extreme head position, peripheral nerve compression, spine flexion or extension, and technical faults (as lead failure and electromagnetic interference) should be ruled out before interpreting the EPs.

In another article published in this issue of Indian Journal of Anaesthesia, Nitin et al.[14] describe the rare experience of successful intraoperative neurophysiological monitoring during pregnancy with no adverse foetal or maternal effects. Normal foetal heart rate and viability was confirmed with continuous cardiotocography and foetal echocardiography during and after the completion of the surgical procedure. No significant changes in MEP amplitude were observed intraoperatively, with no new onset motor or sensory deficits in postoperative period. This case report is valuable as we have a limited experience of intraoperative neuromonitoring during pregnancy.

We hope that these two studies published in the present issue of Indian Journal of Anaesthesia may help physicians to better understand the use of IONM and to improve the safety of patients undergoing spine surgery. EPs may act as biomarkers of neurological injury in the same way as the blood pressure and pulse oximetry monitors are monitors of tissue perfusion and oxygenation. Although we do not have any level I evidence, favouring the use of neurophysiological monitoring, its judicious use as surrogate markers in the intraoperative period (to reduce the neurological morbidity) may be justified by its ability to detect the neural injury and the absence of “second best options” in such scenarios.



 
   References Top

1.
DuBousset J. A tribute to Pierre Stagnara. Spine 1996;21:2176-7.  Back to cited text no. 1
    
2.
Ali Z, Bithal PK. Intra-operative neurophysiological monitoring. J Neuroanaesthesiol Crit Care 2015;2:179-92.  Back to cited text no. 2
  [Full text]  
3.
Holdefer RN, MacDonald DB, Skinner SA. Somatosensory and motor evoked potentials as biomarkers for post-operative neurological status. Clin Neurophysiol 2015;126:857-65.  Back to cited text no. 3
    
4.
Macdonald DB, Skinner S, Shils J, Yingling C, American Society of Neurophysiological Monitoring. Intraoperative motor evoked potential monitoring - a position statement by the American Society of Neurophysiological Monitoring. American Society of Neurophysiological Monitoring. Clin Neurophysiol 2013;124:2291-316.  Back to cited text no. 4
    
5.
Sloan TB. Anaesthesia management and intraoperative electrophysiologic monitoring. In: Koht A, Sloan TB, Toleikis JR, Editors. Monitoring the Nervous System for Anesthesiologists and Other Health Care Professionals. Switzerland: Springer; 2017. p. 317-22.  Back to cited text no. 5
    
6.
Vaugha DJ, Thornton C, Wright DR, Fernandes JR, Robbins P, Doré C, et al. Effects of different concentrations of sevoflurane and desflurane on subcortical somatosensory evoked responses in anaesthetized, non-stimulated patients. Br J Anaesth 2001;86:59-62.  Back to cited text no. 6
    
7.
Pathak KS, Amaddio MD, Scoles PV, Shaffer JW, Mackay W. Effects of halothane, enflurane, and isoflurane in nitrous oxide on multilevel somatosensory evoked potentials. Anesthesiology 1989;70:207-12.  Back to cited text no. 7
    
8.
Peterson DO, Drummond JC, Todd MM. Effects of halothane, enflurane, isoflurane, and nitrous oxide on somatosensory evoked potentials in humans. Anesthesiology 1986;65:35-40.  Back to cited text no. 8
    
9.
Koht A, Schütz W, Schmidt G, Schramm J, Watanabe E. Effects of etomidate, midazolam, and thiopental on median nerve somatosensory evoked potentials and the additive effects of fentanyl and nitrous oxide. Anesth Analg 1988;67:435-41.  Back to cited text no. 9
    
10.
Schubert A, Licina MG, Lineberry PJ. The effect of ketamine on human somatosensory evoked potentials and its modification by nitrous oxide. Anesthesiology 1990;72:33-9.  Back to cited text no. 10
    
11.
Mahmoud M, Sadhasivam S, Salisbury S, Nick TG, Schnell B, Sestokas AK, et al. Susceptibility of transcranial electric motor-evoked potentials to varying targeted blood levels of dexmedetomidine during spine surgery. Anesthesiology 2010;112:1364-73.  Back to cited text no. 11
    
12.
Rozet I, Metzner J, Brown M, Treggiari MM, Slimp JC, Kinney G, et al. Dexmedetomidine does not affect evoked potentials during spine surgery. Anesth Analg 2015;121:492-501.  Back to cited text no. 12
    
13.
Velayutham P, Cherian VT, Rajshekhar V, Babu KS. The effects of propofol and isoflurane on intraoperative motor evoked potentials during spinal cord tumour removal surgery-A prospective randomised trial. Indian J Anaesth 2019;63:92-9.  Back to cited text no. 13
  [Full text]  
14.
Manohar N, Palan A, Manchala RK, Manjunath ST. Intraoperative motor-evoked potentials in a pregnant patient. Indian J Anaesth 2019;63:142-3.  Back to cited text no. 14
  [Full text]  
15.
Kanonidou Z, Karystianou G. Anaesthesia for the elderly. Hippokratia 2007;11:175-7.  Back to cited text no. 15
    
16.
Lieberman JA, Lyon R, Feiner J, Diab M, Gregory GA. The effect of age on motor evoked potentials in children under propofol/isoflurane anaesthesia. Anesth Analg 2006;103:316-21.  Back to cited text no. 16
    




 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Anaesthetic Effe...
    References

 Article Access Statistics
    Viewed470    
    Printed6    
    Emailed0    
    PDF Downloaded272    
    Comments [Add]    

Recommend this journal