Indian Journal of Anaesthesia  
About us | Editorial board | Search | Ahead of print | Current Issue | Past Issues | Instructions
Home | Login  | Users Online: 131  Print this pageEmail this pageSmall font sizeDefault font sizeIncrease font size    


ORIGINAL ARTICLE
Year : 2019  |  Volume : 63  |  Issue : 8  |  Page : 629-634

Ultrasound measurement of anterior neck soft tissue and tongue thickness to predict difficult laryngoscopy - An observational analytical study


Department of Anaesthesia and Critical Care, Institute Block, Jawaharlal Institute of Postgraduate Medical Education and Research, Puducherry, India

Correspondence Address:
Dr. Priya Rudingwa
Department of Anaesthesia and Critical Care, Institute Block, Jawaharlal Institute of Postgraduate Medicine and Research, Puducherry - 605 006
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_270_19

Rights and Permissions

Background and Aims: Airway ultrasound is an emerging tool to predict difficult laryngoscopy. This study aimed to determine the utility of ultrasound measurement of the anterior soft tissue neck thickness at the level of hyoid, thyrohyoid membrane and thickness of tongue to predict difficult laryngoscopy and compare them with clinical parameters for airway assessment. Methods: The distance from skin to hyoid bone, skin to the thyrohyoid membrane in neutral and sniffing position and maximum tongue thickness was measured by ultrasound and correlated with Cormack Lehane (CL) laryngoscope view in 310 adult surgical patients. Receiver operating characteristic curve was plotted and the area under the curve was calculated for each parameter. The sensitivity and specificity of ultrasound-guided parameters were compared with clinical parameters like the inter-incisor gap, modified Mallampatti classification, thyromental, sternomental distance and neck circumference. Results: Incidence of difficult laryngoscopy (CL grade-III and IV) was 11.3%. A significant difference was observed in the ultrasound parameters between the easy and difficult laryngoscopy (P-value = 0.001). Sensitivity and specificity to predict difficult airway was 69.6% and 77% for tongue thickness, 68% and 73% for the skin to hyoid bone distance in a neutral position and found to be higher than clinical parameters. Conclusion: The ultrasound measurements of soft tissue thickness of the anterior neck and tongue thickness along with the clinical assessment of airway can be useful in predicting difficult laryngoscopy.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed246    
    Printed2    
    Emailed0    
    PDF Downloaded92    
    Comments [Add]    

Recommend this journal