COMMENTS ON PUBLISHED ARTICLE
Year : 2020  |  Volume : 64  |  Issue : 6  |  Page : 542-543  

A comment on- 'positive end-expiratory pressure as a novel method to thwart CO2leakage from capnothorax in robotic-assisted thoracoscopic surgery'


Department of Anesthesiology, Critical Care and Pain, Tata Memorial Hospital, Mumbai, Maharashtra, India

Date of Submission19-Feb-2020
Date of Decision03-Apr-2020
Date of Acceptance08-Apr-2020
Date of Web Publication01-Jun-2020

Correspondence Address:
Dr. Swapnil Y Parab
13, Periyar, Anushakti Nagar, Mumbai - 400 012, Maharashtra
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_161_20

Rights and Permissions

How to cite this article:
Parab SY. A comment on- 'positive end-expiratory pressure as a novel method to thwart CO2leakage from capnothorax in robotic-assisted thoracoscopic surgery'. Indian J Anaesth 2020;64:542-3

How to cite this URL:
Parab SY. A comment on- 'positive end-expiratory pressure as a novel method to thwart CO2leakage from capnothorax in robotic-assisted thoracoscopic surgery'. Indian J Anaesth [serial online] 2020 [cited 2020 Jul 7];64:542-3. Available from: http://www.ijaweb.org/text.asp?2020/64/6/542/285526



Sir,

I read, with great interest the case report— 'positive end-expiratory pressure as a novel method to thwart CO2 leakage from capnothorax in robotic-assisted thoracoscopic surgery' by Ravi R et al.[1] According to authors, reported events occurred due to leakage of carbon dioxide (CO2) gas from the pleural cavity into the trachea through a rent in the left lower lobe bronchus. However, this is unlikely if Arndt endobronchial blocker (Cook® Medical) was placed in the left main bronchus and was adequately inflated. In the case, Ravi et al. had not mentioned the volume with which the bronchial cuff of the blocker was inflated. The bronchial cuff of 7 F Arndt blocker takes 2-6 cc of air for adequate inflation.[2] If not inflated properly, there is a possibility of the leak by the side of the cuff and this could have been the reason for CO2 gas to reach the endotracheal tube in the reported case. At the same time, over inflation of the bronchial cuff beyond the recommended volume results in pressure-related ischemic injury to the bronchial mucosa. In such a case, choosing one size larger version of the blocker (i.e., 9F) is a better alternative. [Figure 1] in the case report shows that there was a significant difference between the set (300 ml) and the exhaled tidal volume (237 ml), denoting that bronchial cuff might not be inflated adequately.[1] A leak is more likely with the spherical shape and wrinkled surface of the bronchial cuff.[2] Hence, I suggest that, along with the confirmation of the position of blocker by fibreoptic bronchoscope, authors could have inflated the bronchial cuff to achieve an 'airtight seal'. Airtight seal can be confirmed by eliminating any leak in the tidal volume or by underwater check or by loss of capnography trace from the isolated lung.[3] In robotic thoracic surgery, a sudden jump in end-tidal CO2 can happen if the mainstem bronchus is injured proximal to the inflated bronchial cuff. It would result in loss of tidal volume during inspiration and entry of CO2 from the pleural cavity during the late expiratory phase, depending upon the relationship between airway pressure and pleural pressure. In such a scenario, increasing the end-expiratory pressure more than the capnothorax pressure (as did by the authors in reported case) would prevent CO2 from entering the airway from the pleural cavity. Here, reducing capnothorax pressure should be done as a first step. It should be remembered that excess positive end expiratory pressure (PEEP) can be detrimental to the ventilated lung and can also result in hypotension.

Hence, to conclude, it is very important to confirm the airtight nature of the seal while inflating the bronchial cuff. Understanding the pressure dynamics between the pleural cavity and airway is essential in the management of intraoperative inadvertent bronchial injury.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Ravi R, Senthilnathan M, Sivakumar RK, Suganthapriya C. Positive end-expiratory pressure as a novel method to thwart CO2 leakage from capnothorax in robotic-assisted thoracoscopic surgery. Indian J Anaesth 2020;64:145-7.  Back to cited text no. 1
  [Full text]  
2.
Campos JH. Lung isolation techniques. Anesthesiol Clin North Am 2001;19:455-74.  Back to cited text no. 2
    
3.
Hannallah MS, Benumof JL, McCarthy PO, Liang M. Comparison of three techniques to inflate the bronchial cuff of left polyvinylchloride double-lumen tubes. Anesth Analg 1993;77:990-4.  Back to cited text no. 3
    




 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References

 Article Access Statistics
    Viewed233    
    Printed1    
    Emailed0    
    PDF Downloaded36    
    Comments [Add]    

Recommend this journal