• Users Online: 2074
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2020  |  Volume : 64  |  Issue : 8  |  Page : 681-687

Comparison of glottic visualisation through supraglottic airway device (SAD) using bronchoscope in the ramped versus supine 'sniffing air' position: A pilot feasibility study


1 Department of Anaesthesiology, Singapore General Hospital, Singapore
2 Department of Health Services Research, Singapore General Hospital, Singapore

Correspondence Address:
Dr. Wan Yen Lim
Singapore General Hospital, Outram Road, Singapore - 169608
Singapore
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_320_20

Rights and Permissions

Background and Aims: Airway management in obese patients is associated with increased risk of difficult airway and intubation. After failed intubation, supraglottic airway-guided flexible bronchoscopic intubation (SAGFBI) may be required. It is uncertain whether SAGFBI is best performed in the ramped versus conventional supine “sniffing air” position. We conducted a feasibility study to evaluate the logistics of positioning, compared glottic views, and evaluated SAGFBI success rates. Methods: We conducted a prospective, pilot study in patients with a body mass index (BMI) 30–40 kg/m2 undergoing elective operations requiring tracheal intubation. All patients were placed in a ramped position. After induction, a supraglottic airway device (SAD) was inserted. A flexible bronchoscope was inserted into the SAD and a photograph of the glottic view taken. The patient was repositioned to the supine position. A second photograph was taken. SAGFBI was performed. Images were randomised and assessed by two independent anesthetists. Results: Of 17 patients recruited, 15 patients were repositioned successfully. There were no differences in glottic views observed in the two positions. SAGFBI was successful in 92.9% of patients (median time 91.5 s). Haemodynamic changes were noted in 42.7% of patients which resolved spontaneously. Conclusion: Our pilot study was completed within 5 months, achieved low dropout rate and protocol feasibility was established. SAGFBI was successfully and safely performed in obese patients, with a median time of 91.5 s. The time taken for SAGFBI was similar to awake intubation using FBI and videolaryngoscopy. Our study provided preliminary data supporting future, larger-scale studies to evaluate glottic views in the ramped versus supine positions.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed388    
    Printed10    
    Emailed0    
    PDF Downloaded76    
    Comments [Add]    

Recommend this journal