Indian Journal of Anaesthesia

ORIGINAL ARTICLE
Year
: 2020  |  Volume : 64  |  Issue : 2  |  Page : 131--137

Quantifying influence of epidural analgesia on entropy guided general anaesthesia using sevoflurane – A randomised controlled trial


Murugesan Ravishankar1, Dalena Merin Mathew2, VR Hemanthkumar1, Parthasarathy Srinivasan1 
1 Department of Anesthesiology, Mahatma Gandhi Medical College and Research Institute, Sri Balaji Vidyapeeth University, Puducherry, Tamil Nadu, India
2 Department of Anaesthesiology, PSG Institute of Medical Sciences and Research, Coimbatore, Tamil Nadu, India

Correspondence Address:
Dr. Dalena Merin Mathew
Department of Anaesthesiology, PSG Institute of Medical Sciences and Research, Coimbatore, Tamil Nadu
India

Background and Aims: Minimum alveolar concentration (MAC) of inhalational agent denotes the requirement of it to maintain adequate plane of general anaesthesia. The precision to the maintenance of anaesthesia can be further guided by use of entropy to titrate the depth of anaesthesia. Regional anaesthesia and the concomitant deafferentation will decrease the need of general anaesthetics. We conducted a randomised double-blind trial to quantify the effect of addition of regional anaesthesia to sevoflurane based general anaesthesia technique guided by entropy to achieve satisfactory depth of anaesthesia. Methods: Forty patients posted for elective laparotomies were randomised to two groups. All patients received a bolus followed by an epidural infusion. Group GE (general anaesthesia + epidural bupivacaine) received 0.25% epidural bupivacaine and Group GS received epidural saline. Both groups received narcotic, relaxant and sevoflurane anaesthesia guided by entropy monitoring. The state entropy (SE) was maintained at 40–60 by titrating end tidal sevoflurane concentration (ETsevo). Heart rate, blood pressure, SpO2, end tidal carbon dioxide (ETCO2) and sevoflurane were recorded. Results: Both groups were similar in heart rate and mean blood pressure during anaesthesia maintenance. The minimum ETSevorequired to maintain entropy between 40 and 60 in group GE was 0.53% compared to 0.95% in group GS the epidural saline group (P < 0.001). The end-tidal sevoflurane requirement to maintain adequate depth of anaesthesia dropped by 44.2% in group GE.Conclusion: Lower concentrations of volatile anaesthetic are required when entropy-guided general anaesthesia is combined with regional blockade.


How to cite this article:
Ravishankar M, Mathew DM, Hemanthkumar V R, Srinivasan P. Quantifying influence of epidural analgesia on entropy guided general anaesthesia using sevoflurane – A randomised controlled trial.Indian J Anaesth 2020;64:131-137


How to cite this URL:
Ravishankar M, Mathew DM, Hemanthkumar V R, Srinivasan P. Quantifying influence of epidural analgesia on entropy guided general anaesthesia using sevoflurane – A randomised controlled trial. Indian J Anaesth [serial online] 2020 [cited 2020 May 24 ];64:131-137
Available from: http://www.ijaweb.org/article.asp?issn=0019-5049;year=2020;volume=64;issue=2;spage=131;epage=137;aulast=Ravishankar;type=0