Indian Journal of Anaesthesia

CASE REPORT
Year
: 2020  |  Volume : 64  |  Issue : 2  |  Page : 145--147

Positive end-expiratory pressure as a novel method to thwart CO2 leakage from capnothorax in robotic-assisted thoracoscopic surgery


Ramya Ravi, Muthapillai Senthilnathan, Ranjith K Sivakumar, Chanjeeviram Suganthapriya 
 Department of Anaesthesiology and Critical Care, JIPMER, Pondicherry, India

Correspondence Address:
Dr. Muthapillai Senthilnathan
Department of Anaesthesiology and Critical Care, Hospital Block, Second Floor, JIPMER, Pondicherry - 605 006
India

Abstract

Capnography and end tidal CO2 (EtCO2) aids the anaesthesiologist in diagnosing problems during all phases of general anaesthesia. Negative arterial to end-tidal carbon-dioxide gradient during anaesthesia has been reported in various conditions including pregnancy, infants and inadvertent exogenous addition of carbon dioxide (CO2) to the expired gas in case of thoracoscopic procedures with iatrogenic injury to lung parenchyma/bronchial tree. Thus, airway injury or intentional opening of airway as a part of surgical step can be diagnosed using a negative arterial and end tidal CO2 gradient. Higher optimal PEEP can be used as a splint across the bronchial cuff in one-lung ventilation which prevents leak from capnothorax and decrease inadvertent entry of CO2 in to the expired gases which erroneously increase arteriolar to end tidal CO2 gradient.



How to cite this article:
Ravi R, Senthilnathan M, Sivakumar RK, Suganthapriya C. Positive end-expiratory pressure as a novel method to thwart CO2 leakage from capnothorax in robotic-assisted thoracoscopic surgery.Indian J Anaesth 2020;64:145-147


How to cite this URL:
Ravi R, Senthilnathan M, Sivakumar RK, Suganthapriya C. Positive end-expiratory pressure as a novel method to thwart CO2 leakage from capnothorax in robotic-assisted thoracoscopic surgery. Indian J Anaesth [serial online] 2020 [cited 2020 Sep 23 ];64:145-147
Available from: http://www.ijaweb.org/text.asp?2020/64/2/145/277762


Full Text



 Introduction



Negative arterial to end-tidal carbon-dioxide gradient during anaesthesia is reported in various conditions including pregnancy, infants, and inadvertent exogenous addition of carbon dioxide (CO2) to the expired gas in thoracoscopic procedures with iatrogenic injury to lung parenchyma.[1],[2],[3] We discuss a case of robotic-assisted thoracoscopic surgery with negative arterial-EtCO2 gradient, its intraoperative concern, and a novel management technique.

 Case Report



A 59-year-old female of height 156 cm with carcinoma of lung left lower lobe was posted for left lower lobectomy. Her preoperative assessment revealed adequate cardiopulmonary reserve and had predicted postoperative Forced Expiratory Volume (FEV1) of 58%. Anaesthetic plan included thoracic epidural analgesia and general anaesthesia. During intubation there was difficulty in negotiation of tracheal cuff of 35- French left sided double lumen tube (DLT) through the glottis. Hence a 7-French bronchial blocker (Arndt- Cook® Medical) was chosen for lung isolation. A 7.5 mm endotracheal tube was placed through which bronchial blocker was placed in left main bronchus guided by a fibreootic bronchoscope (FOB). Position of the bronchial blocker and isolation of left lung was ensured by FOB in right-lateral position. After docking of the Robotic da Vinci Xi® surgical system, capnothorax was created in left pleural cavity with pressure of 8 mmHg. Commencement of dissection of left lower bronchus resulted in sudden increase in EtCO2 with intermittent normal range of EtCO2. Patient's heart rate, saturation (SpO2), blood pressure, temperature, and airway pressure were stable throughout the procedure. Arterial blood gas revealed partial pressure of CO2 (PaCO2) of 45 mmHg. Suspecting increased systemic absorption of CO2 from capnothorax, respiratory rate was increased to increase minute-ventilation [tidal volume-300 ml, respiratory rate – 18.min-1, positive end-expiratory pressure (PEEP) 4 cm H2O]. Few minutes later, EtCO2 continued to rise up to 114 mmHg [Figure 1]a with PaCO2 of 42 mmHg. At this point, the left lung remained collapsed and bronchial cuff position was confirmed by FOB. On inspection, open left lower lobe bronchus communicating with capnothorax was suspected to be the cause for negative arteriolar to EtCO2 gradient [Figure 1]b. The surgeon was notified regarding the same and the capnothorax pressure was reduced to 5 mmHg (6.5 cmH2O). PEEP was increased to 8 cmH2O thereby reversing the pressure gradient across the open bronchus and proximal bronchial cuff. These manoeuvres led to the reduction in efflux of capnothorax CO2 into the airway which was reflected in EtCO2. Thoracoscopic lobectomy was continued and rest of the procedure was uneventful.{Figure 1}

 Discussion



Capnography along with electrocardiogram (ECG), blood pressure, SpO2, temperature, peak airway pressure, plateau airway pressure, arterial partial pressure of oxygen (PaO2), and PaCO2 are generally used in arriving at a specific diagnosis for intraoperative rise in EtCO2 under general anaesthesia [Table 1]. A sudden rise in EtCO2 in patients undergoing robotic-assisted thoracoscopic lobectomy with OLV can be associated with CO2 embolism and lung/airway injury.[2],[4],[5] CO2 embolism, though rare, can be seen commonly at the time of CO2 insufflation into the pleural cavity. It is diagnosed with the help of clinical features secondary to abnormalities in gas exchange and increased right ventricular afterload. However, it is also possible that CO2 embolism may present with decreased EtCO2 due to the “gas lock” effect. Although CO2 embolism is seen commonly during initial period of insufflation, a sudden rise in EtCO2 due to lung/airway injury can occur during the middle of the surgery during dissection. The insufflation CO2 can escape through the injured open airway (bronchial tree) and reaches capnometer with the expired gases causing rise in EtCO2. This differs from CO2 embolism in that the PaCO2 in embolism remains higher and the gradient between the PaCO2 and EtCO2 remains the same or only slightly increased.[5] Whereas in “lung/airway injury” there is a significant rise in EtCO2 with near normal PaCO2.[2] A negative PaCO2 to EtCO2 gradient associated with a sudden rise in EtCO2 in a thoracoscopic lobectomy points toward a possible airway injury and rules out other differential diagnosis such as CO2 embolism and malignant hyperthermia wherein the gradient remains positive. Other possible causes for a negative arteriolar to end-tidal CO2 gradient can be seen in infants and patients with decreased functional residual capacity especially when they are ventilated with higher tidal volume at lower respiratory rate.[6] In our case, the insufflation CO2 entered through the damaged bronchial tree [Figure 1]b, causing the EtCO2 level reaching a peak of 114 mmHg with arterial CO2 tension of 41 mmHg at that point of time. The primary issue with CO2 leak into the bronchial tree was that the capnothorax pressure was inadequate for the surgeon to operate with ease. This made them to increase the CO2 flow and capnothorax pressure which further increased the leak around the bronchial cuff causing a further rise in EtCO2. Therefore, encountering negative arteriolar to end-tidal CO2 gradient in a thoracoscopic procedure should act as a clue toward possible airway damage which should be communicated to the surgeon promptly for early repair. More often the damage goes unnoticed and the thoracoscopic procedure gets converted to an open procedure as the cause for a sudden rise in EtCO2 cannot be found. A simple way to avoid this scenario would be to quickly rule out other possible treatable causes and once diagnosis of airway injury is made, we suggest to increase the PEEP,[7] which can act as a splint, preventing CO2 leak around the bronchial cuff [Figure 1]b. In our case, to prevent the inadvertent leak around the bronchial cuff, we reversed the pressure gradient by increasing the PEEP to 8 cmH2O and reducing the capnothorax pressure to 5 mmHg [Figure 1]c and 1d].[8] It was immediately followed by a steady decrease in EtCO2 to 45 mmHg. Similarly, in case of DLT and a leak around bronchial cuff through an injured bronchial tree, the PEEP at the tracheal lumen can be increased to prevent the leak. Therefore, diagnosing airway injury or intentional opening of airway as a part of surgical step using a negative arterial-EtCO2 gradient and managing the leak using optimally higher than normal PEEP can be used to prevent unnecessary conversion of thoracoscopic procedures to an open surgery.{Table 1}

Declaration of patient consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.

References

1MD BS. Negative (a-ET)PCO2 differences [Internet]. Capnography. Available from: https://www.capnography.com/physiology/negative-a-etpco2-differences. [Last cited on 2019 Jun 17].
2Amin RM, Alkhashti MG, Galhotra K, Al-Sharhan A, Al-Manfohi H. Elevated end-tidal carbon dioxide during thoracoscopy. MedGenMed 2002;4:7.
3Onodi C, Bühler PK, Thomas J, Schmitz A, Weiss M. Arterial to end-tidal carbon dioxide difference in children undergoing mechanical ventilation of the lungs during general anaesthesia. Anaesthesia 2017; 72:1357-64.
4Ohtsuka T, Imanaka K, Endoh M, Kohno T, Nakajima J, Kotsuka Y, et al. Hemodynamic effects of carbon dioxide insufflation under single-lung ventilation during thoracoscopy. Ann Thorac Surg 1999;68:29-32.
5Tran DT, Badner NH, Nicolaou G, Sischek W. Arterial pCO2 changes during thoracoscopic surgery with CO2 insufflation and one lung ventilation. HSR Proc Intensive Care Cardiovasc Anesth 2010;2:191-7.
6Karnik P, Kulkarni K, Dave N, Garasia M. Mind the gap!!: Reversal of arterial to end-tidal CO2 gradient in thoracoscopic bronchogenic cyst excision. Indian J Anaesth 2017;61:181.
7Michelet P, Roch A, Brousse D, D'journo XB, Brégeon F, Lambert D, et al. Effects of PEEP on oxygenation and respiratory mechanics during one-lung ventilation. Br J Anaesth 2005;95:267-73.
8Pinto V, Galketiya K. Insufflation pressure required for thoracoscopic surgery and its influence on respiratory and cardiovascular parameters. Sri Lankan J Anaesthesiol 2014;22:55-8.