• Users Online: 987
  • Print this page
  • Email this page
ORIGINAL ARTICLE
Year : 2016  |  Volume : 60  |  Issue : 5  |  Page : 330-336

Acoustic puncture assist device versus loss of resistance technique for epidural space identification


Department of Anaesthesiology and Critical Care, Rajiv Gandhi Cancer Institute and Research Centre, New Delhi, India

Correspondence Address:
Amit Kumar Mittal
A 3/225, Sector-5, Rohini, New Delhi - 110 085
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.181594

Clinical trial registration CTRI/2014/09/004963) dated 03/09/2014

Rights and Permissions

Background and Aims: The conventional techniques of epidural space (EDS) identification based on loss of resistance (LOR) have a higher chance of complications, patchy analgesia and epidural failure, which can be minimised by objective confirmation of space before catheter placement. Acoustic puncture assist device (APAD) technique objectively confirms EDS, thus enhancing success, with lesser complications. This study was planned with the objective to evaluate the APAD technique and compare it to LOR technique for EDS identification and its correlation with ultrasound guided EDS depth. Methods: In this prospective study, the lumbar vertebral spaces were scanned by the ultrasound for measuring depth of the EDS and later correlated with procedural depth measured by either of the technique (APAD or LOR). The data were subjected to descriptive statistics; the concordance correlation coefficient and Bland-Altman analysis with 95% confidence limits. Results: Acoustic dip in pitch and descent in pressure tracing on EDS localisation was observed among the patients of APAD group. Analysis of concordance correlation between the ultrasonography (USG) depth and APAD or LOR depth was significant (r ≥ 0.97 in both groups). Bland-Altman analysis revealed a mean difference of 0.171cm in group APAD and 0.154 cm in group LOR. The 95% limits of agreement for the difference between the two measurements were − 0.569 and 0.226 cm in APAD and − 0.530 to 0.222 cm in LOR group. Conclusion: We found APAD to be a precise tool for objective localisation of the EDS, co-relating well with the pre-procedural USG depth of EDS.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2295    
    Printed14    
    Emailed0    
    PDF Downloaded499    
    Comments [Add]    

Recommend this journal