Intubation outcomes using the aerosol box during the COVID-19 pandemic: A prospective, observational study


1 Department of Anaesthesia, Pain and Palliative Care, Chennai, Tamil Nadu, India
2 Department of Surgical Oncology, Cancer Institute (WIA), Chennai, Tamil Nadu, India

Date of Submission30-Dec-2020
Date of Decision01-Feb-2021
Date of Acceptance22-Feb-2021
Date of Web Publication13-Mar-2021

Correspondence Address:
Meenakshi V Venketeswaran
Department of Anaesthesia, Pain and Palliative Care, Cancer Institute (WIA), Dr. S. Krishnamurthi Campus, No. 38, Sardar Patel Road, Chennai, Tamil Nadu - 600 036
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_1578_20

Rights and Permissions
 


Background and Aims: The aerosol box (AB), an improvised device used during the coronavirus disease (COVID)-19 pandemic, has attracted both interest and controversy. Several simulated studies have examined its protective efficacy as well as intubation efficiency. The aim of this study was to evaluate the practical conduct of intubation using the AB in patients undergoing elective, oncological surgery during the pandemic. Methods: This prospective, observational study included adult patients undergoing oncological surgery. Thirteen anaesthesiologists performed 132 intubations using one of three ABs designated as AB 1, AB 2 and AB 3. The primary outcome was the difference in the time to intubation (TTI) between patients with Mallampati score MP I-II (Group 1) and MP III-IV (Group 2). Secondary outcomes included first-pass success rate, fall in peripheral oxygen saturation to < 95%, total number of attempts and failure to intubate using the AB. Results: The mean TTI was not significantly different in Group 1 and Group 2 (71.02 (61.66) s vs. 101.35 (121.94) s respectively, P = 0.119). Desaturation during intubation was seen in 20 patients (15.1%). First pass success rate was achieved in 109 patients (82.6%). Twenty-one patients (15.9%) needed more than one attempt to intubate and the box had to be removed in 8 patients (6.1%) for facilitating intubation. The Mallampati score did not significantly influence either desaturation or first pass success rate. Conclusion: There was a non-significant increasing TTI trend in patients with a higher MP score with the use of an aerosol box. However, this did not translate to a clinically significant difference in the overall intubation outcomes.

Keywords: Aerosol, anaesthetists, COVID-19, intubation, prospective study


How to cite this article:
Venketeswaran MV, Srinivasaraghavan N, Balakrishnan K, Seshadri RA, Sriman S. Intubation outcomes using the aerosol box during the COVID-19 pandemic: A prospective, observational study. Indian J Anaesth 2021;65:221-8

How to cite this URL:
Venketeswaran MV, Srinivasaraghavan N, Balakrishnan K, Seshadri RA, Sriman S. Intubation outcomes using the aerosol box during the COVID-19 pandemic: A prospective, observational study. Indian J Anaesth [serial online] 2021 [cited 2021 Jun 14];65:221-8. Available from: https://www.ijaweb.org/text.asp?2021/65/3/221/311196




   Introduction Top


The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) causing coronavirus disease (COVID)-19 emerged in December 2019. The virus rapidly swept across the world due to its high transmissibility as compared to other epidemic coronaviruses.[1] Aerosols, droplets and direct contact transfer had been implicated in transmission of coronaviruses.[2] Amongst the aerosol-generating procedures (AGPs), tracheal intubation was found to be consistently associated with transmission of the SARS-CoV in a systematic review.[3] The global scale and velocity of the COVID-19 pandemic led to several measures to protect health care workers (HCWs). These included use of negative pressure rooms, adherence to airborne precautions and personal protective equipment (PPE) and using barrier enclosures for tracheal intubation.[4] The aerosol box (AB) used during tracheal intubation is a transparent, semi-open, cuboidal barrier device used to shield the airway manager from airborne particles. Canelli et al. in their study of the aerosol box demonstrated that the majority of the infectious secretions are contained within the box and the disposable gloves/sleeves of the anaesthetist[5] making it a useful adjunct to PPE. Guidelines state that caution should be exercised in patients with a difficult airway.[6]

Though the aerosol box is an ingenious device, its utility and performance have been questioned.[7] Majority of the studies pertaining to the AB are simulation-based and its clinical implications are being explored.[8],[9]

There is a lingering fear of exposing a patient with a potentially difficult airway to hypoxia by using the AB, and with this in mind we planned a study aimed to document the intubation outcomes using the AB in a spectrum of patients including those with a potentially difficult airway in a clinical setting.


   Methods Top


This was a prospective, observational, single-centre study. The study was approved by our Institutional Ethics Committee and was registered in the Clinical Trials Registry of India (CTRI/2020/07/026610). Written informed consent was obtained from all the study participants for using the AB and the collected data for academic purposes. All patients above 18 years of age undergoing oncological surgeries under general anaesthesia by rapid sequence intubation from July to September 2020 were included. Both orotracheal and nasotracheal intubations were eligible. Only procedures performed by qualified anaesthesiologists with at least 1-year clinical experience, all of whom were familiar with the use of AB were included for this study. Anaesthesiologists were allowed to use the conventional Macintosh Laryngoscope (DL) or the C-MAC™ video laryngoscope (VL) (Karl Storz, Tuttlingen, Germany) D-Blade based on the availability. Patients who did not fit within the aerosol box due to their body habitus, requiring fibreoptic guided intubation, undergoing emergency surgery with risk for gastric aspiration, or requiring double-lumen tube insertion were excluded.

Consecutive patients planned for surgery under general anaesthesia were screened during the pre-anaesthetic visit. Only those testing negative for SARS-CoV-2, were taken up for surgery. The institutional COVID standard operating procedure (SOP) for anaesthesia and operation theatre was followed.[6],[10] Three different ABs were used during this period [Figure 1]. All boxes had a thick, transparent plastic drape covering the open end. AB1 and AB2 were commercially available and had, in addition to disposable sleeves mounted on the apertures, an in-built suction port for creating some negative pressure inside. The third box (AB3) which resembled the early-generation box was locally manufactured and we improvised it by adding the drape and placing the Yankauer suction tip inside the box during intubation and extubation. The AB was disinfected after each use as per our infection control policy.
Figure 1: Specifications of the aerosol boxes used during the study

Click here to view


The attending anaesthesiologist and anaesthesia assistant were donned in PPE for airborne precautions (N-95 mask, face shield, fluid-resistant jumpsuit with hood, and double gloves). An intravenous access and standard monitoring were established. Patient's head was rested on a soft head-ring. One of the three available ABs was placed over the patient's head and preoxygenation commenced with oxygen 5 l.min-1 and adjustable pressure limiting valve set at 10 cm H2O pressure for 5 minutes. Height of the operating room table was adjusted to facilitate clear vision through the AB panel. The laryngoscope was positioned within the box. Patients were then administered fentanyl 1–1.5 μg.kg-1, propofol 2-3 mg.kg-1 followed by a bolus of suxamethonium 1.5 mg.kg-1 or rocuronium 1 mg.kg-1. Simultaneously the assistant started the timer on the monitor and the trachea was intubated 60 s later using a DL/VL. The assistant was instructed to pause the gas flows during the conduct of intubation and aid in giving the endotracheal tube (ETT), inflate the cuff and restore gas supply and commence mechanical ventilation. The assistant also performed additional manoeuvres as required by the anaesthesiologist. In the event of any difficulty, the use of intubation aids (bougie/stylet), change in approach (adjustment of the head position, external laryngeal manipulation, need for second assistant, nasotracheal vs orotracheal), plan modification (change of laryngoscope, tube, fibreoptic bronchoscopy, laryngeal mask airway) and removing the aerosol box were left to the discretion of the attending anaesthesiologist. The timelines were recorded by the backup anaesthesiologist. The attending anaesthesiologist documented his/her perception of ease of intubation using the AB in a specially prepared questionnaire. The AB was also used during extubation.

The primary outcome was the difference in the time to intubation[8] between patients with Mallampati score MP I-II (Group 1) and MP III-IV (Group 2) (defined as the time from when the laryngoscope blade passes between the patient's incisors until the first upstroke on the capnograph trace). Secondary outcomes included first-pass success rate (defined as successful insertion of the DL or VL and ETT by an anaesthesiologist in the first-attempt without withdrawing from the mouth in no longer than 150 seconds), fall in saturation from the time of removal of the oxygen mask to delivering the first breath to peripheral oxygen saturation (SpO2) <95%, total number of attempts at intubation and failure to intubate using aerosol box (defined as the need to remove the aerosol box in order to achieve successful intubation).

Prior to the commencement of this study, we undertook a retrospective audit of 47 patients who had received general anaesthesia using the AB, based on which a sample size of 30 patients each with MP I-II and MP III-IV was deemed necessary to detect an absolute difference of 20 s in the mean time to intubation using a two-sided Z-test of the difference in means with 80% power and a 5% significance level.

Continuous variables were reported as mean ± standard deviation (SD) or median (Interquartile range (IQR)) while categorical variables were reported as frequency (percentage). Variables influencing TTI were subjected to the student t-test and a multivariable linear regression model was created with factors that achieved significance. Logistic regression analysis was carried out to determine the relative importance of variables affecting the saturation. Differences in the TTI between AB were analysed using Analysis of Variance (ANOVA). Descriptive statistics was done for the other outcomes. A P value <0.05 was considered significant. Statistical analysis was done using the Statistical Package for the Social Sciences International Business Machines (IBM-SPSS) version 26.0 (IBM, Armonk, NY, USA).


   Results Top


One hundred and thirty-six eligible patients were anaesthetised using one of 3 ABs of which, 132 patients with complete data were included in this study. Thirteen anaesthesiologists participated in the study and 74 (56.1%) intubations were carried out by anaesthesiologists with ≥5 years experience. Patient demographics are depicted in [Table 1]. The mean age of the patients was 52.56 (10.95) years and the ratio of female to male patients were 100:32. Twenty-six patients (19.7%) had a body mass index (BMI) ≥30.
Table 1: Patient demographics and its distribution in the three aerosol boxes

Click here to view


In all patients, the mean TTI was 81.59 (88.23) [Table 2] while the mean TTI in Groups 1 and 2 were 71.02 (61.66) s vs. 101.35 (121.94) s respectively, P = 0.119. The TTI did not follow a normal distribution and the analysis was repeated after removing the outliers (TTI >150s), but we were not able to demonstrate a significant difference in the mean TTI between Group 1 and Group 2 (56.27 (27.59) vs. 65.37 (30.57) s; P = 0.101). This is depicted in [Supplemental Table 1]. Eighty patients were intubated in <60s, 110 in less than 120s, 119 patients within 150s and 13 patients in ≥150s. The mean TTI was significantly longer in AB2 (108.85 (127.32)) when compared to AB1 (63.86 (40.6); P = 0.014) and AB3 (69.3 (60.8); P = 0.035). On univariate analysis, factors found to significantly influence the TTI were the type of laryngoscope, Cormack-Lehane (CL) grade, and use of intubation aids, change of approach, plan modification and type of AB [Table 3]. However, on multivariable analysis, only AB2, use of intubation aids, change of approach and plan modification emerged as independent predictors of the TTI [Table 3].
Table 2: Intubation outcomes

Click here to view

Table 3: The factors influencing time to intubation (TTI)

Click here to view


Desaturation was observed only in 20 patients (15.1%) overall. BMI ≥30 kg.m-2 and a change of approach were independently associated with a risk of desaturation (Odds ratio (95%CI) 5.98 (1.43-25.00) and 6.023 (0.646-56.12) respectively) [Table 4]. First-pass success rate, which is a measure of both the number of attempts and TTI <150 s, was achieved in 109 (82.6%) patients [Table 2]. Intubation at first attempt was achieved in 111 patients whereas 19 patients required two attempts and 2 patients required three attempts. A higher number of patients in AB2 required more than one attempt (n = 13) when compared to AB1 (n = 3) and AB3 (n = 5). The AB was removed in 8 (6.1%) patients for facilitating intubation.
Table 4: Factors influencing desaturation (SpO2<95%)

Click here to view


A qualitative feedback from the anaesthesiologists showed that in 72% of intubations the anaesthesiologists experienced varying degrees of stress while using the AB. The AB was reported by the anaesthesiologists to reduce their ability to access the laryngoscope, ability to introduce the ETT into the glottis and ability to view the chest movements in 22%, 12.8% and 15% of patients respectively.


   Discussion Top


We demonstrated that in a pandemic situation where an AB was used as part of other measures to reduce the risk of exposure to anaesthesiologists during tracheal intubation, the time to intubation was not significantly different between patients with MP I-II and MP III-IV. To the best of our knowledge, this is the first clinical study that has shown that the AB can be safely used even in patients with a potentially difficult airway. The outcomes using an AB have been mostly reported in simulated situations using manikins where it has been shown to prolong the TTI.[11],[12],[13],[14] A Canadian manikin-based simulation study reported that the mean time to intubation in a difficult airway scenario was increased with an AB compared to without (34.4s vs 27.3s, mean difference 7.1%; 95%CI, –2.5 to 16.7).[14] The only clinical trial using the AB was a non-inferiority randomised trial which reported that the mean TTI in patients with and without an AB was 52.1 (95% CI, 26.1–78) vs. 42 (95% CI, 19.2–64.8) s, respectively (P = 0.046).[9] The authors concluded that the delay in TTI with the AB was well within the safe period of apnoea tolerated by most patients. However, this study did not report outcomes specifically in patients with a difficult airway.

Factors predicting a longer TTI in our patients were use of intubation aids (bougie/stylet), use of AB2, change of approach and plan modification. Intubation aids can shorten the TTI if used appropriately. In our study, intubation aids were mostly used only after a failed first attempt at intubation, hence prolonging the TTI. Different ABs have been known to influence the TTI.[11] The AB2 used in this study, although a later generation one compared to AB3, had a higher number of patients with a difficult airway when compared to the other two which could probably explain the longer TTI with this box.

Other factors that contributed to a prolonged TTI included use of PPE and occasional fogging of the eyewear which has been shown to complicate tracheal intubation.[10] Further, since the open portion of all ABs was covered, it had to be lifted by the assistant for all additional manoeuvres which added to the TTI. Our VL was only equipped with a D-blade which can prolong TTI in a normal airway.[15] In contrast, in a recent study using the AB, videolaryngoscopy was found to be easier than direct laryngoscopy in patients with no co-morbidities, BMI ≤30, and MP score I-II.[8]

Despite the longer TTI and the fact that the patients did not receive bag and mask ventilation while apnoeic, only 20 patients (15.2%) desaturated of which 13 patients had SpO2 <90%. While some studies on apnoeic oxygenation have defined desaturation as SpO2 ≤90%, we felt that a higher safety margin of SpO2 <95% would be desirable. The mandatory five minutes of preoxygenation could have increased the safe apnoea time of most patients. BMI ≥30 was independently predictive of desaturation whereas the TTI was not. It has been reported that patients with BMI ≥30 are at risk for arterial desaturation once they become apnoeic[16] and that the safe apnoea period in such patients is also lower than patients with normal weight (2-3 min vs. 8-10 min).[17] In spite of desaturation, none of the patients had an adverse outcome.

The first pass success rate in our study was 82.6%. Other studies using ABs in simulated and real patients had success rates between 38-100%.[9],[11],[12],[13],[14],[18]

The AB has certain advantages. Besides potentially reducing exposure to aerosols, it is sturdy, sustainable and easy to clean.[19] It can be customised to the place of use at a low cost. However, it can also pose certain challenges like difficulty in using intubation aids and Magill's forceps,[14],[20] increased first pass failure,[21] restriction of forearm movement and migration of the box. Use of the AB can lead to stress among the anaesthesiologists as evident from the feedback obtained in this study. Participants in one simulated study did not find the AB challenging to use but would not use it in a difficult airway[14] whereas participants in another study were mostly or very unsatisfied as they experienced difficulties with the AB.[12] Nearly 50% of anaesthesiologists reported discomfort while using the AB and 33% reported increased cognitive load from use of the box in simulated intubations.[11]

The skewed distribution of the TTI was not unexpected and the outliers were deliberately not removed as this was not a manikin study and intended to be a real time representation. There are several limitations in this study. It was not a randomised controlled trial (RCT) of intubation outcomes in patients with and without using an AB, although such a study was not possible in our centre because of ethical concerns. It was subject to multiple confounding factors with regards to the different ABs, patient factors, equipment and operator factors. The association of the TTI with the usage of intubation aids and AB2 should not be over-interpreted as this was an observational study. It is possible that the sample size to identify differences in the intubation outcomes in a difficult airway is much larger given that MP score alone does not predict a difficult airway. We did not examine the protective efficacy of the AB or its use in a critical care or emergency scenario. The strength of our study is that it has objectively captured the performance of the AB in the real world and its relative generalisability in a limited resource setting. An RCT comparing intubation in difficult airways with and without AB is warranted in the future.


   Conclusion Top


In this single-centre study, we observed a non-significant increasing TTI trend in patients with a higher MP score when compared to a lower score when using the aerosol box. However, this did not translate to a clinically significant difference in the overall intubation outcomes between the two groups.

Acknowledgements

We wish to thank Dr Swaminathan Rajaraman and Dr. Rama Ranganathan, Department of Biostatistics and Epidemiology for their guidance with the statistical analysis. We would also like to thank our other colleagues in the Department of Anaesthesia for their participation.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Petersen E, Koopmans M, Go U, Hamer DH, Petrosillo N, Castelli F, et al. Comparing SARS-CoV-2 with SARS-CoV and influenza pandemics. Lancet Infect Dis 2020;20:e238-44.  Back to cited text no. 1
    
2.
Odor PM, Neun M, Bampoe S, Clark S, Heaton D, Hoogenboom EM, et al. Anaesthesia and COVID-19: Infection control. Br J Anaesth 2020;125:16-24.  Back to cited text no. 2
    
3.
Tran K, Cimon K, Severn M, Pessoa-Silva CL, Conly J. Aerosol generating procedures and risk of transmission of acute respiratory infections to healthcare workers: A systematic review. PLoS One 2012;7:e35797.  Back to cited text no. 3
    
4.
Wong J, Goh QY, Tan Z, Lie SA, Tay YC, Ng SY, et al. Preparing for a COVID-19 pandemic: A review of operating room outbreak response measures in a large tertiary hospital in Singapore. Can J Anaesth 2020;67:732-45.  Back to cited text no. 4
    
5.
Canelli R, Connor CW, Gonzalez M, Nozari A, Ortega R. Barrier enclosure during endotracheal intubation. N Engl J Med 2020;382:1957-8.  Back to cited text no. 5
    
6.
Patwa A, Shah A, Garg R, Divatia J, Kundra P, Doctor J, et al. All India difficult airway association (AIDAA) consensus guidelines for airway management in the operating room during the COVID-19 pandemic. Indian J Anaesth 2020;64:107-15.  Back to cited text no. 6
  [Full text]  
7.
Sorbello M, Rosenblatt W, Hofmeyr R, Greif R, Urdaneta F. Aerosol boxes and barrier enclosures for airway management in COVID-19 patients: A scoping review and narrative synthesis. Br J Anaesth 2020;125:880-94.  Back to cited text no. 7
    
8.
Puthenveettil N, Rahman S, Vijayaraghavan S, Suresh S, Kadapamannil D, Paul J. Comparison of aerosol box intubation with C-MAC video laryngoscope and direct laryngoscopy-A randomised controlled trial. Indian J Anaesth 2021;65:133-8.  Back to cited text no. 8
  [Full text]  
9.
Madabhushi P, Kinthala S, Ankam A, Chopra N, Porter BR. Time to adapt in the pandemic era: A prospective randomized non –inferiority study comparing time to intubate with and without the barrier box. BMC Anesthesiol 2020;20:232.  Back to cited text no. 9
    
10.
Cook TM, El-Boghdadly K, McGuire B, McNarry AF, Patel A, Higgs A. Consensus guidelines for managing the airway in patients with COVID-19: Guidelines from the Difficult Airway Society, the Association of Anaesthetists the Intensive Care Society, the Faculty of Intensive Care Medicine and the Royal College of Anaesthetists. Anaesthesia 2020;75:785-99.  Back to cited text no. 10
    
11.
Begley JL, Lavery KE, Nickson CP, Brewster DJ. The aerosol box for intubation in coronavirus disease 2019 patients: An in-situ simulation crossover study. Anaesthesia 2020;75:1014-21.  Back to cited text no. 11
    
12.
Aletreby WT, Alharthy AM, Madi AF, Ramadan OE, Alodat MA, Huwait BM, et al. Impact of aerosol box on duration of intubation of COVID-19 patients: Simulation cross-over study. Int J Health Sci Res 2020;10:22-7.  Back to cited text no. 12
    
13.
Wakabayashi R, Ishida T, Yamada T, Kawamata M. Effect of an aerosol box on tracheal intubation difficulty. J Anesth 2020;34:790-3.  Back to cited text no. 13
    
14.
Fong S, Li E, Violato E, Reid A, Gu Y. Impact of aerosol box on intubation during COVID-19: A simulation study of normal and difficult airways. Can J Anaesth 2020:1-9. doi: 10.1007/s12630-020-01825-y.  Back to cited text no. 14
    
15.
Kilicaslan A, Topal A, Erol A, Uzun ST. Comparison of the C-MAC D-Blade, conventional C-MAC, and macintosh laryngoscopes in simulated easy and difficult airways. Turk J Anaesthesiol Reanim 2014;42:182-9.  Back to cited text no. 15
    
16.
Members of the Working Party; Nightingale CE, Margarson MP, Shearer E, Redman JW, Lucas DN, Cousins JM, et al. Peri-operative management of the obese surgical patient 2015: Association of Anaesthetists of Great Britain and Ireland Society for Obesity and Bariatric Anaesthesia. Anaesthesia 2015;70:859-76.  Back to cited text no. 16
    
17.
Brodsky JB. Recent advances in anesthesia of the obese patient. F1000Res 2018;7:F1000. doi: 10.12688/f1000research. 15093.1.  Back to cited text no. 17
    
18.
Ponnappan KT, Sam AF, Tempe DK, Arora MK. Intubation box in the current pandemic-helps or hinders? Anaesth Crit Care Pain Med 2020;39:587-8.  Back to cited text no. 18
    
19.
Asokan K, Babu B, Jayadevan A. Barrier enclosure for airway management in COVID-19 pandemic. Indian J Anaesth 2020;64:153-4.  Back to cited text no. 19
  [Full text]  
20.
Maniar A, Jagannathan B. The aerosol box. J Anaesthesiol Clin Pharmacol 2020;36:141-3.  Back to cited text no. 20
  [Full text]  
21.
Singh B, Singla S, Gulia P, Kumar A, Bhanwala R. Aerosol containment device for use on suspected COVID-19 patients. Indian J Anaesth 2020;64:154-6.  Back to cited text no. 21
  [Full text]  


    Figures

  [Figure 1]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    Abstract
   Introduction
   Methods
   Results
   Discussion
   Conclusion
    References
    Article Figures
    Article Tables

 Article Access Statistics
    Viewed714    
    Printed4    
    Emailed0    
    PDF Downloaded119    
    Comments [Add]    

Recommend this journal